Reshaper, how to change blade

Advertisement

2.
How to change the Front Blade Unit
2-1 Prepare new Front Blade Set(L720FB1A)
to replace with the one removed.
2-2 How to change the Blade Receptacle Plate
As shown in the below picture, remove Entry Guide(2screws), Film Press Plate(2screws) and Blade
Receptacle Plate(1screw)
Pull out the  Blade Receptacle Plate by lifting it up towards the back.
Entry Guide・Film Press Plate・Blade Recep. Plate
2-3 How to assemble Film Guide Section
N.B. 1.Assemble to the Film Guide Section with care.  Be sure on the matching pitches of screws.
        Assemble it in the reversed order of detaching.
When attaching the Film Press Plate, adjust the holes of Blade Receptacle Plate and Film Press Plate.
Assemble the Entry Guide by sliding it from the left of the Film Press Plate.(Below, arrow marked)
After assembling, check whether or not the Film Positioning Plunger will return to the original position 
by pushing the Film Positioning Plunger(click-stopped) and Lock Pin.
Entry Guide
Removed Front Blade Unit
Holes of Blade Receptacle 
Plate and Film Press Plate
New Front Blade Set(L720FB1A)
   Blade Receptacle Plate
Lock Pin Film Positioning Plunger
- 2 -