Nectre Fireplaces Baker's Oven Installation & Operating Instructions Manual page 5

Table of Contents

Advertisement

CONSTRUCTING THE FLUE
The Nectre Bakers Oven must be installed with a standard 4.2M long Masport flue system with a
dropbox or flue system with a dropbox that has been tested and comply with AS/NZS 2918:2001, Appendix
F. Also, the main flue pipe should be fitted with a 900mm long 180° arc or 900mm long Masport
stainless steel double flue shield.
The flue kit should be made of stainless steel or vitreous enameled steel, and it shall extend
not less than 4.6m above the top of the floor protector and meets the requirements of
AS2918/2001. The length will depend on ceiling height and roof design, but the top of the flue
pipe must be a minimum of 600mm above the ridge of the roof if the flue penetrates the roof
within 3m of the ridge. Or to be of sufficient height to be 3m from the roofline horizontally, but a
minimum height of 1m.
If the draft is insufficient or periodic down drafting occurs, and the appliance smokes or only
burns slowly, extending the flue or fitting a specialised cowl will usually cure it.
Where the flue penetrates the ceiling and roof, it must comply with AS2918:2001. If the baker's
oven is fitted to an existing chimney, ensure that it is sealed at the base of the chimney with a
register plate and fit the flue pipe up through the plate and continue until it terminates outside
the chimney in accordance with AS2918:2001 4.9.1.
The flue kit must be installed according to the manufacturer's instructions.

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Nectre Fireplaces Baker's Oven

Table of Contents