The information contained in this document supersedes all similar information that
may be found elsewhere in this manual.
Service – Due to the sophisticated
nature of the sensors and associated
instrumentation
provided
Piezotronics, user servicing or repair is
not recommended and, if attempted,
may void the factory warranty. Routine
maintenance, such as the cleaning of
electrical connectors, housings, and
mounting surfaces with solutions and
techniques that will not harm the
physical material of construction, is
acceptable. Caution should be observed
to ensure that liquids are not permitted
to migrate into devices that are not
hermetically
sealed.
should only be wiped with a dampened
cloth and never submerged or have
liquids poured upon them.
Repair – In the event that equipment
becomes
damaged
operate, arrangements should be made
to
return
the
equipment
Piezotronics for repair. User servicing or
repair is not recommended and, if
attempted,
may
warranty.
Calibration – Routine calibration of
sensors and associated instrumentation
is recommended as this helps build
confidence in measurement accuracy
and
acquired
calibration
cycles
established by the users own quality
regimen. When in doubt about a
calibration cycle, a good "rule of thumb"
is to recalibrate on an annual basis. It is
by
PCB
Such
devices
or
ceases
to
to
PCB
void
the
factory
data.
Equipment
are
typically
Service, Repair, and Return
Policies and Instructions
also good practice to recalibrate after
exposure to any severe temperature
extreme,
shock,
environmental influence, or prior to any
critical test.
PCB Piezotronics maintains an ISO-
9001 certified metrology laboratory and
offers calibration services, which are
accredited by A2LA to ISO/IEC 17025,
with full traceability to SI through
N.I.S.T. In addition to the normally
supplied calibration, special testing is
also available, such as: sensitivity at
elevated or cryogenic temperatures,
phase response, extended high or low
frequency response, extended range,
leak
testing,
hydrostatic
testing, and others. For information on
standard
recalibration
special testing, contact your local PCB
Piezotronics
distributor,
representative,
or
service representative.
Returning
Equipment
these procedures will ensure that your
returned materials are handled in the
most
expedient
returning
any
equipment
Piezotronics,
contact
distributor,
sales
factory customer service representative
to obtain a Return Warranty, Service,
Repair, and Return Policies and
Instructions
Materials
(RMA) Number. This RMA number
should be clearly marked on the outside
of all package(s) and on the packing
load,
or
other
pressure
services
or
sales
factory
customer
Following
manner.
Before
to
PCB
your
local
representative,
or
Authorization

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICP 410C01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PCB Piezotronics ICP 410C01

  • Page 1 Piezotronics, user servicing or repair is critical test. not recommended and, if attempted, may void the factory warranty. Routine PCB Piezotronics maintains an ISO- maintenance, such as the cleaning of 9001 certified metrology laboratory and electrical connectors, housings, and offers calibration services, which are...
  • Page 2 50% of the general contact numbers are: replacement cost returned item(s). PCB will provide a price PCB Piezotronics, Inc. quotation replacement 3425 Walden Ave. recommendation for any item whose Depew, NY14043 USA repair costs would exceed 50% of...
  • Page 3 PCB工业监视和测量设备 - 中国RoHS2公布表 PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 有害物质 汞 镉 六价铬 (Cr(VI)) 多溴联苯 (PBB) 多溴二苯醚 (PBDE) 部件名称 铅 (Pb) (Hg) (Cd) 住房 PCB板 电气连接器 压电晶体 环氧 铁氟龙 电子 厚膜基板 电线 电缆 塑料 焊接...
  • Page 4 Component Name Hazardous Substances Lead Mercury Cadmium Chromium VI Polybrominated Polybrominated (Pb) (Hg) (Cd) Compounds Biphenyls Diphenyl (Cr(VI)) (PBB) Ethers (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
  • Page 5  MODEL 410C01 ICP SENSOR SIGNAL CONDITIONER OPERATION MANUAL Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043-2495  Phone (716) 684-0001 Fax (716) 684-0987  Info@pcb.com www.pcb.com Manual Number:68840 Manual Revision: A ECN Number 49884...
  • Page 6: Table Of Contents

     MODEL 410C01 ICP SENSOR SIGNAL CONDITIONER OPERATION MANUAL Table of Contents Introduction Page 3 Installation Page 3 Connector and Pinout Diagram Page 4 Typical System Wiring Diagram Page 5 24-Volt DC Supply Power Page 5 Configuration Software Page 5 Waveform Output (±10 V Analog) Page 6 Peak Hold Output (0-10 VDC)
  • Page 7: Introduction

     MODEL 410C01 ICP SENSOR SIGNAL CONDITIONER OPERATION MANUAL Introduction  PCB Model 410C01 Series Signal Conditioner is designed to condition and amplify output signals generated by ICP sensors, such as force and strain sensors and accelerometers. The signals are converted to a ±10 V analog output that is relative to the force, strain, or motion applied to the transducer.
  • Page 8: Connector And Pinout Diagram

     MODEL 410C01 ICP SENSOR SIGNAL CONDITIONER OPERATION MANUAL Connector and Pinout Diagram The 410C01 uses plug-in type screw terminal connectors for all input and output connections. Strip off 8mm of insulation from the connection wire ends. Using a screwdriver, remove the terminal block from the enclosure in either the up or down direction, terminate the wire in the correct location.
  • Page 9: Typical System Wiring Diagram

     MODEL 410C01 ICP SENSOR SIGNAL CONDITIONER OPERATION MANUAL Typical System Wiring Diagram Waveform Analog Output +10V Peak Hold Analog Output +10 V ® 410C01 ICP Signal Conditioner PWR Ground 24 VDC Supply Power The 410C01 requires a regulated 24-volt DC power supply that is capable of providing up to 200 mA of current per unit connected to pins 10 (+) and 11 (-).
  • Page 10: Waveform Output (±10 V Analog)

     MODEL 410C01 ICP SENSOR SIGNAL CONDITIONER OPERATION MANUAL Waveform Output (±10 V Analog) Optionally connect the Waveform output to the host system (ensure polarity is correct for proper operation). The waveform  output is a live active output and represents the force, strain, or motion imparted to the connected ICP sensor.
  • Page 11: Ac/Dc Coupling

     MODEL 410C01 ICP SENSOR SIGNAL CONDITIONER OPERATION MANUAL AC/DC Coupling The downloadable software for the 410C01, allows the option to configure unit for AC or DC coupling as seen in the figure shown below. For High-Speed applications, where the signal pulse widths are ≤ 0.01 seconds, configure the unit to AC Coupling.
  • Page 12: Gain Selection

     MODEL 410C01 ICP SENSOR SIGNAL CONDITIONER OPERATION MANUAL Gain Selections The supplied software for the 410C01, allows the option to configure the gain levels of the Waveform Output in steps of 1X, 2X, 4X,8X,10X,16X and 20X as seen in the figure shown below. The module is factory supplied with a gain of 1X. Please reference the Help menu on the software when utilizing the Gain function.
  • Page 13  MODEL 410C01 ICP SENSOR SIGNAL CONDITIONER OPERATION MANUAL Log Viewer (continued) Capture Parameters Trigger Type: Choose between Analog and Digital Trigger Edge: Choose between Rising and Falling Edge Trigger Levels: Enter a percentage of maximum voltage level Capture Time: Enter number of seconds to capture real-time data Start Capture: Click the Start Capture button to begin capturing and downloading real-time data to the computer Measurement Parameters Time Line 1: Sets, in milliseconds, the “Start”...
  • Page 14: Maintenance

     MODEL 410C01 ICP SENSOR SIGNAL CONDITIONER OPERATION MANUAL Maintenance This product does not require maintenance or calibration and there are no adjustments with the exception of software selection of Gain and Attenuation.  Sensors are extremely sensitive devices. If the sensor torque is changed (i.e. transducer removed/re-installed), for certain applications it may be necessary to confirm the scaling in the host monitoring and control system.
  • Page 15: Contact Information

    Contact Information For product application, technical information, or service, contact: PCB Piezotronics, Inc. 3425 Walden Avenue, Depew, New York 14043-2495 USA Toll-free telephone: 800-828-8840 or 716-684-0001...
  • Page 16 All specifications are at room temperature unless otherwise specified. 3425 Walden Avenue, Depew, NY 14043 In the interest of constant product improvement, we reserve the right to change specifications without notice. ® is a registered trademark of PCB Piezotronics, Inc.
  • Page 17 PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. UPDATED GND IN TABLE 49884 TERMINAL CONNECTION PEAK HOLD OUT...