Page 2
Required corrections are contained in the following regulations or can be downloaded on the Internet. The current version is available for download on our web site www.iba-ag.com. Copyright notice Windows® is a label and registered trademark of the Microsoft Corporation. Other product and company names mentioned in this manual can be labels or registered trademarks of the corresponding owners.
System topologies................... 12 5.2.1 System without ibaBM-COL-8i-o..............12 5.2.2 System with ibaBM-COL-8i-o................13 5.2.3 Hardware connection without using iba Software ........... 14 5.2.4 Saving FO cables.................... 15 Configuration in ibaPDA-V6 ................16 Installation, Connection, Disassembly............17 lnstallation ....................... 17 Connection ...................... 17 Disassembly....................
Manual ibaBM-COL-8i-o About this manual This manual describes the construction, the use and the operation of the device ibaBM-COL-8i-o. Target group This manual addresses in particular the qualified professionals who are familiar with handling electrical and electronic modules as well as communication and measurement technology.
Manual Used symbols If safety instructions or other notes are used in this manual, they mean: The non-observance of this safety information may result in an imminent risk of death or severe injury: • By an electric shock! •...
Manual ibaBM-COL-8i-o Scope of delivery After unpacking check the completeness and intactness of the delivery. The scope of delivery includes: Device ibaBM-COL-8i-o 2-pole connector (WAGO order no. 231-532/108-000) Manual Safety instructions Designated use The device is electrical equipment. It may be used only in the following applications:...
512 analog and 512 digital values and transmitted in the so called X-mode with 32 Mbit/s to the fiber optic output. Therefore, an iba FOB-X card or iba FOB-D card must be inserted in the receiving ibaPDA or ibaLogic-PC.
Manual ibaBM-COL-8i-o Front view Mirror output (TX-X11) LEDs (L34 to L37) Input channels (RX-X34 to RX-X37) Indication of the operating status (L1 to L4) On/Off switch (S11) 24 V power supply (X14) Output channel TX (X10) Optional input for future extensions (RX-X20)
Manual ibaBM-COL-8i-o Display elements Colored LEDs on the device indicate the operating status and the status of 8 inputs. Operating status Status Description L1: Green Blinking Ready for operation, power supply is on Out of order, no power supply L2: Yellow Is lit...
Note If all inputs of an ibaFOB-X-card are operated at the maximum capacity, some values can get lost during data transfer. Therefore, it is recommended to use the latest iba technology standard of the ibaFOB-D-cards with the device. System topologies 5.2.1...
Manual 5.2.2 System with ibaBM-COL-8i-o In this example only 1 input is required for the same data volume as in the previous example. The other 3 inputs can be used for further devices. Figure 6: System with ibaBM-COL-8i-o Issue 1.1...
Hardware connection without using iba Software The figure below shows for example how 2 automation systems can exchange data via a mere hardware connection. There is no need for an iba software application. The bidirectional data exchange between an ABB AC 800PEC controller and a SIMADYN D 16bit system is realized by a combination of ibaLink-SM-64-SD16 system interface boards and the devices ibaBM-COL-8i-o and ibaBM-DIS-i-8o.
Manual 5.2.4 Saving FO cables If you plan to save numbers of fiber optic cables, particularly over long distances, you can connect an ibaBM-DIS-i-8o device on the output side which takes 1 cable with 32 Mbit/s and distributes its signals on 8 cables with 3.3 Mbit/s each. Just one cable is needed for the long distance and you’ve saved 7 cables.
Configuration in ibaPDA-V6 If the device is connected to the ibaPDA-V6 system, then it is automatically detected by the software. The devices connected to ibaBM-COL-8i-o on the input links are also detected. In the I/O manager of ibaPDA-V6 the device is represented in the signal tree as shown on the picture below.
Manual Installation, Connection, Disassembly lnstallation Insert the clip of the mounting rail fastened on the device into the mounting rail. Press the device down in such a way that the clip of the mounting rail engages with a click.
Manual ibaBM-COL-8i-o Technical data Main data Manufacturer iba AG, Germany Order number 13.114000 Power supply DC 24 V, ±10 % unstabilized; 0.1 A Power consumption < 3 W Service interface USB (bottom side of the device) Mechanical stability DIN IEC 68-2-6 (in case of correct installation) Operating temperature range 32 °F to 122 °F (0 °C to +50 °C)
Page 19
Manual Connectable devices Input side ibaPADU series ibaPADU-8 ibaPADU-8-HI ibaPADU-8-I ibaPADU-16 ibaPADU-32-R ibaPADU-32 ibaLink series ibaLink-SM-64-i-o ibaLink-SM-128V-i-2o ibaLink-SM-64-SD16 ibaBM series ibaBM-SLM ibaBM-DDCSM ibaBM-DPM-64 ibaBM-DPM-S-64 ibaDIG-40 ibaNet750-BM ibaFOB cards ibaFOB-io-S ibaFOB-4o ibaFOB-4o-PCI Output side ibaFOB-4i-X ibaFOB-2i-X ibaFOB-2io-X ibaFOB-4i-D ibaFOB-2io-D Automation components with integrated 32 Mbit/s input channel, e.
Manual Accessories Product iba order number Comment Fiber optic cable Simplex with the ST- 50.101050 connectors, length 196.85 inch (5 m) For further fiber optic cables and other products refer to iba product catalog on www.iba-ag.com. Issue 1.1...
Koenigswarterstr. 44 90762 Fuerth Germany Phone: +49 911 97282-0 Fax: +49 911 97282-33 Email: iba@iba-ag.com Contact: Mr. Harald Opel Regional and Worldwide For contact data of your regional iba office or representative please refer to our web site www.iba-ag.com. Issue 1.1...