Advertisement

Quick Links

ibaBM-COL-8i-o
Manual
ibaBM-COL-8i-o
Data concentrator
Manual
Issue 1.1
Issue 1.1
1

Advertisement

Table of Contents
loading

Summary of Contents for IBA ibaBM-COL-8i-o

  • Page 1 Manual ibaBM-COL-8i-o Data concentrator Manual Issue 1.1 Issue 1.1...
  • Page 2 Required corrections are contained in the following regulations or can be downloaded on the Internet. The current version is available for download on our web site www.iba-ag.com. Copyright notice Windows® is a label and registered trademark of the Microsoft Corporation. Other product and company names mentioned in this manual can be labels or registered trademarks of the corresponding owners.
  • Page 3: Table Of Contents

    System topologies................... 12 5.2.1 System without ibaBM-COL-8i-o..............12 5.2.2 System with ibaBM-COL-8i-o................13 5.2.3 Hardware connection without using iba Software ........... 14 5.2.4 Saving FO cables.................... 15 Configuration in ibaPDA-V6 ................16 Installation, Connection, Disassembly............17 lnstallation ....................... 17 Connection ...................... 17 Disassembly....................
  • Page 4: About This Manual

    Manual ibaBM-COL-8i-o About this manual This manual describes the construction, the use and the operation of the device ibaBM-COL-8i-o. Target group This manual addresses in particular the qualified professionals who are familiar with handling electrical and electronic modules as well as communication and measurement technology.
  • Page 5: Used Symbols

    Manual Used symbols If safety instructions or other notes are used in this manual, they mean: The non-observance of this safety information may result in an imminent risk of death or severe injury: • By an electric shock! •...
  • Page 6: Scope Of Delivery

    Manual ibaBM-COL-8i-o Scope of delivery After unpacking check the completeness and intactness of the delivery. The scope of delivery includes: Device ibaBM-COL-8i-o 2-pole connector (WAGO order no. 231-532/108-000) Manual Safety instructions Designated use The device is electrical equipment. It may be used only in the following applications:...
  • Page 7: Product Features

    512 analog and 512 digital values and transmitted in the so called X-mode with 32 Mbit/s to the fiber optic output. Therefore, an iba FOB-X card or iba FOB-D card must be inserted in the receiving ibaPDA or ibaLogic-PC.
  • Page 8: Front View

    Manual ibaBM-COL-8i-o Front view Mirror output (TX-X11) LEDs (L34 to L37) Input channels (RX-X34 to RX-X37) Indication of the operating status (L1 to L4) On/Off switch (S11) 24 V power supply (X14) Output channel TX (X10) Optional input for future extensions (RX-X20)
  • Page 9: Bottom View

    Manual Bottom view The bottom side of the device contains: Service interface (USB) Earth connection Figure 3: Bottom view Issue 1.1...
  • Page 10: Display Elements

    Manual ibaBM-COL-8i-o Display elements Colored LEDs on the device indicate the operating status and the status of 8 inputs. Operating status Status Description L1: Green Blinking Ready for operation, power supply is on Out of order, no power supply L2: Yellow Is lit...
  • Page 11: Block Diagram

    Manual Block diagram Figure 4: Block diagram Data concentrator Output Mirror output Issue 1.1...
  • Page 12: Systems And Design

    Note If all inputs of an ibaFOB-X-card are operated at the maximum capacity, some values can get lost during data transfer. Therefore, it is recommended to use the latest iba technology standard of the ibaFOB-D-cards with the device. System topologies 5.2.1...
  • Page 13: System With Ibabm-Col-8I-O

    Manual 5.2.2 System with ibaBM-COL-8i-o In this example only 1 input is required for the same data volume as in the previous example. The other 3 inputs can be used for further devices. Figure 6: System with ibaBM-COL-8i-o Issue 1.1...
  • Page 14: Hardware Connection Without Using Iba Software

    Hardware connection without using iba Software The figure below shows for example how 2 automation systems can exchange data via a mere hardware connection. There is no need for an iba software application. The bidirectional data exchange between an ABB AC 800PEC controller and a SIMADYN D 16bit system is realized by a combination of ibaLink-SM-64-SD16 system interface boards and the devices ibaBM-COL-8i-o and ibaBM-DIS-i-8o.
  • Page 15: Saving Fo Cables

    Manual 5.2.4 Saving FO cables If you plan to save numbers of fiber optic cables, particularly over long distances, you can connect an ibaBM-DIS-i-8o device on the output side which takes 1 cable with 32 Mbit/s and distributes its signals on 8 cables with 3.3 Mbit/s each. Just one cable is needed for the long distance and you’ve saved 7 cables.
  • Page 16: Configuration In Ibapda-V6

    Configuration in ibaPDA-V6 If the device is connected to the ibaPDA-V6 system, then it is automatically detected by the software. The devices connected to ibaBM-COL-8i-o on the input links are also detected. In the I/O manager of ibaPDA-V6 the device is represented in the signal tree as shown on the picture below.
  • Page 17: Installation, Connection, Disassembly

    Manual Installation, Connection, Disassembly lnstallation Insert the clip of the mounting rail fastened on the device into the mounting rail. Press the device down in such a way that the clip of the mounting rail engages with a click.
  • Page 18: Technical Data

    Manual ibaBM-COL-8i-o Technical data Main data Manufacturer iba AG, Germany Order number 13.114000 Power supply DC 24 V, ±10 % unstabilized; 0.1 A Power consumption < 3 W Service interface USB (bottom side of the device) Mechanical stability DIN IEC 68-2-6 (in case of correct installation) Operating temperature range 32 °F to 122 °F (0 °C to +50 °C)
  • Page 19 Manual Connectable devices Input side ibaPADU series ibaPADU-8 ibaPADU-8-HI ibaPADU-8-I ibaPADU-16 ibaPADU-32-R ibaPADU-32 ibaLink series ibaLink-SM-64-i-o ibaLink-SM-128V-i-2o ibaLink-SM-64-SD16 ibaBM series ibaBM-SLM ibaBM-DDCSM ibaBM-DPM-64 ibaBM-DPM-S-64 ibaDIG-40 ibaNet750-BM ibaFOB cards ibaFOB-io-S ibaFOB-4o ibaFOB-4o-PCI Output side ibaFOB-4i-X ibaFOB-2i-X ibaFOB-2io-X ibaFOB-4i-D ibaFOB-2io-D Automation components with integrated 32 Mbit/s input channel, e.
  • Page 20: Dimension Sheet

    Manual ibaBM-COL-8i-o Dimension sheet (Dimensions in mm) Figure 1: Dimension sheet Issue 1.1...
  • Page 21: Accessories

    Manual Accessories Product iba order number Comment Fiber optic cable Simplex with the ST- 50.101050 connectors, length 196.85 inch (5 m) For further fiber optic cables and other products refer to iba product catalog on www.iba-ag.com. Issue 1.1...
  • Page 22: Support And Contacts

    Koenigswarterstr. 44 90762 Fuerth Germany Phone: +49 911 97282-0 Fax: +49 911 97282-33 Email: iba@iba-ag.com Contact: Mr. Harald Opel Regional and Worldwide For contact data of your regional iba office or representative please refer to our web site www.iba-ag.com. Issue 1.1...

Table of Contents