Operation Instructions

Preparation

1.
Ask the owner for vehicle drivability problems and
symptoms, wheel alignment history, and find out
vehicle information such as make, model and
year, etc.
2.
Drive the vehicle onto the lift or over the pit,
ensure that the front wheels are centered with the
turntables; Apply hand brake to ensure human
safety. To prevent the turntable from turning, lock
the turntables with the lock pins before driving the
vehicle; release the lock pins after the vehicle is
placed well.
3.
Check each chassis part carefully, include dust
cover, bearing, rock arm, tripod end, shock
absorber, tie rod end and steering mechanism,
for any looseness or wear. Then check to see if
the tire pressure and track widths of the left and
right wheels are alike.
4.
Install the wheel clamp-target assembly on the
wheel and turn the knob to lock the wheel clamp.
The claws of the wheel clamp should be fixed on
the external or internal edge of the rim according
to the practical condition. Ensure equal depth for
each claw and avoid attaching it on the distorted
area. Use the safety belt to bind the wheel clamp
to the wheel rim to avoid falling accidentally.
Please see Fig.4.1.
Fig.4.1
5.
Insert the power plug of the wheel aligner into the
standard 3-pole power receptacle.

Program Operation

Turn on the power switch, start the computer and enter
the main interface of the measurement program. The
screen displays the main function menu. There are 7
functions available in the main menu: [Standard
measurement],
[Quick
measurement],
measurement], [System management], [Print], [Help],
KWA-300 3D Wheel Aligner
and [Exit]. See Fig.4.2

Standard Measurement

Click [Standard Measurement] in the interface as shown
in Fig.4.2. The screen system will enter the standard
measurement interface.

Select Vehicle Model

Before alignment, the standard data of the vehicle model
must be selected first. The interface is as shown in
Fig.4.3:
Commonly used data list
Quick search
[Next]: To perform the test according to the default
sequence (Select vehicle model → Vehicle-pushing
compensation → Caster swing → Rear axle →
Front axle → Print report ) of the system.
[Navigation column]: To enter into the item you want
to test in spite of the default sequence.
[Commonly used data list]: The vehicle model in the list
can be directly selected to perform the next-step
operation. It is blank when firstly used. Only the vehicle
model data must be added into this list from the
[Additional
standard database, can the list be used (See [System
4-1
Operation Instructions
Fig.4.2
Navigation column
Added from
standard data
Fig.4.3
Tire parameter
Help
Next