SLEIPNER MOTOR AS SIDE-POWER PJC-322 Installation And User Manual

Thruster systems s-link control panel

Advertisement

Quick Links

SIDE-POWER
Thruster Systems
Installation and user's manual
GB
Installasjons og brukermanual
N
SLEIPNER MOTOR AS
P.O. Box 519
N-1612 Fredrikstad
Norway
Tel:
Fax:
+47 69 30 00 60
+47 69 30 00 70
PJC-322/321
Control Panel
w w w . s i d e - p o w e r . c o m
s i d e p o w e r @ s l e i p n e r. n o
S-link
© Sleipner Motor AS 2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIDE-POWER PJC-322 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SLEIPNER MOTOR AS SIDE-POWER PJC-322

  • Page 1 . s i d e - p o w e r . c o m Fax: +47 69 30 00 70 s i d e p o w e r @ s l e i p n e r. n o © Sleipner Motor AS 2010...
  • Page 2: Can-Bus Connection

    PJC-322 / 321 ™ Control panel with S-link CAN-bus connection Product features • For proportional thruster control with the new S-Link controlled Hydraulic Thrusters • Back-lit LCD display with instant feedback System status Amount of thrust & direction of thrust Oil temperature & pressure • Interactive multi-language menus • CAN-Bus communication with thrusters and accessories • Plug & play cables, waterproof and compact connectors • Diagnostics via panel • Connector for external “buzzer”/loud audible alarms DISPLAY IN NORMAL USE: 1 hydraulic tank 2 hydraulic tanks Oil Temperature Oil Temperature, Oil Temperature, Port Tank...
  • Page 3 DISPLAY WARNINGS & ALARMS: FILTER MONITORING WARNINGS (IF SENSORS ARE INSTALLED) PRESSURE FILTER: Pressure filter symbol (upper right) will blink when filter change is due. In addition red LEDs on both sides of the panel will blink and the external buzzer is activated. RETURN FILTER: Return filter symbol (lower right) will blink when the filter needs to be replaced. In addition red LEDs on both sides of the panel will blink and the external buzzer is activated. The external buzzer can be muted by pressing the button under the loud- speaker symbol. Warnings will be reset when the filter are replaced. The thrusters can be run while the warnings is displayed. (Filter warnings will not be shown on systems with two oil tanks) ALARMS (Systems with one oil tank) OIL LEVEL: Oil level symbol (upper left) will blink when oil level is low. In addition red LEDs on both sides of the panel will blink and the external buzzer is activated. The alarm will be reset automatically when the oil level is OK OIL TEMPERATURE: Oil temperature symbol (lower left) will blink when temperature is above 75 o C. In addition red LEDs on both sides of the panel will blink and the external buzzer is acti- vated. The alarm will be reset automatically when temperature goes below 65 o C The thrusters can be run when the oil alarms are active.
  • Page 4: Emergency Stop

    EMERGENCY STOP: When the STOP button is pressed, the hydraulic dump valve will activate and the thrusters will stop. On systems with two oil tanks, dump valves on both tanks will activate and all thrusters will stop. The EMERGENCY STOP ACTIVATED sybol will be shown on the display. In addition red LEDs on both sides of the panel will blink and the external buzzer is activated. NB: FOR EMERGENCY STOP ONLY! Press STOP again to reactivate the hydraulic system. The external buzzer can be muted by pressing the button under the loud- speaker symbol. MENU SYSTEM: Access menu system by pressing menu button SETTINGS The menu system contains of 5 settings: 1 - Cooling Pump 2 - Pump Settings 3 - Language 4 - Display Settings 5 - Automatic OFF time...
  • Page 5 3/5 Language Choose between English, Norwegian, German, French, Spanish or Italian. The setting will not affect other panels in the system. 4/5 Display settings Set contrast and backlight level for Daytime/Night modes Settings will not affect other panels in the system. Press to start adjustment - Press + or - to adjust contrast or backlight. Use to switch between daytime or night settings. End setting by pressing Adjustments will automatically end after 3 seconds of inactivity. 5/5 Automatic OFF time Set time from last activity to Panel automatically turns off. The time can be set at 5 minutes interval, ranging from 5 to 60 minutes - or be disabled. When “Disabled” is selected, the panel will never be turned off auto- matically. Settings will not affect other panels in the system. Press to adjust time in 5 minutes intervals. End setting by pressing Store settings by pressing PJC-212 1.0.0- 2010...
  • Page 6 SERVICE MENU (Systems with one oil tank) Access SERVICE MENU by pressing MENU button and hold it for 5 Seconds Shows oil pressure and temperature in the hydraulic tank as well as the serial number of the panel. Thrusters can be operated while this display is shown. Exit Service Menu by pressing SERVICE MENU (Systems with two oil tanks) Shows oil pressure and temperature in both hydraulic tanks as well as the serial number of the panel. Thrusters can be operated while this display is shown. Exit Service Menu by pressing TECHNICAL SPECIFICATIONS, LCD DISPLAY: IP 67 Low temp functionality (-40 o C) Mounting bracket Alarm output max load 200mA...
  • Page 7 Measurements PJC-212 1.0.0- 2010...
  • Page 8: Service Centres

    Fax: +44 1364 649 399 www.imtra.com Fax: +385 51 704 600 andy@sleipner.co.uk side-power@imtra.com acyachting@gmail.com Sleipner Motor AS • P. O. Box 519, N-1612 Fredrikstad • Norway Tel: +47 69 30 00 60 • Fax: +47 69 30 00 70 • sidepower@sleipner.no • www.side-power.com...