Installation; Spindle Amplifier Installation - Mitsubishi Electric MDS-B-SPJ2 Series Specification Manual

Ac spindle drive unit
Table of Contents

Advertisement

4.2 Installation

1. Install the unit on noncombustible material. Direct installation on combustible material or near
combustible materials could lead to fires.
2. Follow this manual and install the unit in a place where the weight can be borne.
3. Do not get on top of or place heavy objects on the product.
4. Use the unit under the designated range of environment conditions.
5. Do not let conductive objects such as screws or metal chips, etc., or combustible materials such as
oil enter the spindle amplifier.
6. Do not block the suction and ventilation ports of the spindle amplifier. Unit failure may occur if these
are blocked.
7. The spindle amplifier and spindle motor are precision devices, so do not drop them or apply strong
impacts to them.
8. Do not operate a spindle amplifier or spindle motor that is damaged or missing parts.
9. Before using this product after a long period of storage, please contact the Mitsubishi Service
Station or Service Center.

4.2.1 Spindle amplifier installation

1. Always observe the installation direction. Failure to observe this will result in unit failure.
2. Secure the specified space between the spindle amplifier and inside wall of the control panel, and
between the other devices. Failure to observe this will result in unit failure.
(1) Environment conditions
Environment
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Atmosphere
Altitude
Vibration
4. Handling
CAUTION
CAUTION
0°C to +55°C (with no freezing)
90%RH or less (with no freezing)
−20°C to +65°C (with no freezing)
90%RH or less (with no freezing)
Indoors (where the unit is not subject to direct sunlight)
With no corrosive gas, combustible gas, oil mist or dust
1000m or less above sea level
2
5.9m/s
(0.6G) or less
4 − 2
Condition