Assembly Instructions
4. Install Duct and Blower Assembly
4.
a) Install duct from the inside of the housing. Fix the duct by the tab
4.
b) Fix the blower assembly to the housing by 3 screws
5. Install Round Ductwork
4.
a) Connect the round ductwork (not included) to the damper / duct
5. a)
connector, and run the ductwork to a roof or wall cap (not included)
4.
b) Using tape (not included), secure all the ductwork connections so
5. b)
that they are airtight
5.
c) Insulated flexible duct is recommended for the quietest possible
5. c)
installation. If rigid duct is used, a short (1-3 feet) section of insulated
5. c)
flexible duct will ensure quiet operation
The ducting from this fan to the outside of building has a strong effect on
the airflow, noise and energy use of the fan. Use the shortest, straightest
duct routing possible for best performance, and avoid installing the fan
with smaller ducts than recommended. Insulation around the ducts can
reduce energy loss and inhibit mold growth. Fans installed with existing
ducts may not achieve their rated airflow.
info@ortechindustries.com
www.ortechindustries.com

Retrofit Installation

1. Remove wire panel and blower assembly before installation
2. Fold mounting ears flat against housing
3. Enlarge ceiling opening to 9-1/2" by 9-1/2".
Leave ductwork and wiring in place
4. Connect wiring according to the WIRING DIAGRAM on page
5 of this instruction manual.
Re-install wire panel
5. Mounting Fan:
a) the interior of the fan housing contains additional
a)
mounting holes in case exterior mounting is not possible.
a)
Screw or nail the fan housing directly to the framing or
a)
joists. Remove the blower assembly as directed in the
a)
service parts on the very last page of this instruction
a)
manual to gain access to the additional mounting holes
b) Mount with Hole of the Flange:
b)
Use screws (included) to screw fans to the ceiling
b)
through the holes of the housing
6. Connect Duct:
Pull existing ducting through housing discharge opening and
tape ducting to duct connector. Push connector / ducting
back through opening, fix the duct by the tab
7. Install the blower assembly