Section 6. Measurements - GE PVDB-28kV Instructions Manual

Distribution vacuum circuit breaker, spring operating mechanism
Table of Contents

Advertisement

Distribution
Breaker
Section 6. Measurements and Adjustments
~
.,..-OPERATINC
~OD
.I l
2
EROSION
DISC.
5
6
3
-;r::zr;::;..rL
OC K NUT
=
~
\~~EROSION
INDICATOR
REFERENCE
ARM
4
~I
--
1.
HEXAGON PROJECTION
2.
OPERATING ROD INSULATOR
3.
WIPE SPRING
4.
EROSION INDICATOR
5.
EROSION DISK
6. WIPE INDICATOR
(Shown in closed position with no contact erosion)
Figure 11. Erosion Indicator
~
CTUATOR
ARM
TRIP ARM
ACTUATOR
ARM
I
'~ ~
~
IP ARM
[TRIP
PIN
(:\
I e
ADJUSTING NUT~
~
I
LOCKING CLIP,
(BEND CORNER
I
AGAINST
TRIP PIN
ADJUSTING
NUT)
LOCKING (BEND CORNER AGAINST
CLIP
ADJUSTING NUT)
:;~~-
ADJUS TING NUT
"T
~
L.ftt
-
COil ASH:--
DEPRESS
PLUNGER
l
TO.25~:8gg L
GAP
~~lL
PLUNGI:-j~~~~~~
1-
BASE
1
STOP BRACKET---1
-tkl
~
--COIL
ASH.
rDEPRESS
PLUNGER
-1- TO.25~:8~GAP
tb-r§~;§::::PLUNGER BASE
TRIP
COIL
#"2
TRIP COIL"
Figure 12. Trip Coil and Linkage