SIGN INSTALLATION MANUAL
Models: 3225, 4225
Built‐In Data Amplifier
      

Advertisement

loading

Summary of Contents for Pro Lite Marquee-Lite PLUS 3225

  • Page 1 SIGN INSTALLATION MANUAL Models: 3225, 4225 Built‐In Data Amplifier       ...
  • Page 2 INTRODUCTION CONGRATULATIONS The Marquee-Lite PLUS is the finest retrofit messaging center available on the market ™ today. It is available in two sizes, a 6 foot (ML3225) or 8 foot (ML4225) unit. The Marquee- Lite Plus (ML+) is designed for ease of use, ease of installation, and years of trouble free ™...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS PACKING LIST ………………..……………………………………………………………………………………….. 1 SIGN CONFIGURATION – MASTER ONLY …………………………………………………………………… 2 SIGN CONFIGURATION – MASTER/SLAVE ………………………………………………………………….3 SIGN INSTALLATION & AC POWER CONNECTIONS ………………………………………………………4 TEMPERATURE SENSOR INSTALLATION ………..…………………………………………………………..5 - 6 CUSTOMER SERVICE - WARRANTY …………………………………………………………………………….7...
  • Page 4: Packing List

    PACKING LIST SIGN Remote Temperature Sensor Case Remote and Installation Manual Data Cable (1 per sign) Page 1...
  • Page 5: Sign Configuration - Master Only

    SIGN CONFIGURATION – MASTER ONLY The ML+ is designed to operate as an independent unit (MASTER ONLY), or operate two ML+ units (MASTER/ SLAVE) controlled by a single remote control. Follow the instructions in this section to operate the ML+ as a MASTER ONLY configuration. 1) Locate the MASTER INPUT and OUTPUT1 ports on the back, left side of the ML+ MASTER ML+ (Backside) 2) Using the supplied Data Cable, connect as shown below.
  • Page 6: Sign Configuration - Master/Slave

    SIGN CONFIGURATION – MASTER/SLAVE Follow the instructions in this section to operate two ML+ units as a MASTER/SLAVE configuration. NOTE : Any ML+ unit can be configured as MASTER or SLAVE. It is important to note that the MASTER will always be the primary signal carrier. 1) Configure one ML+ as a MASTER ONLY configuration.
  • Page 7: Sign Installation & Ac Power Connections

    SIGN INSTALLATION & AC POWER CONNECTIONS SIGN INSTALLATION 1) Slide the unit(s) into your cabinet. 2) Confirm that all Data Cable connections are secure. 3) Finish securing the unit(s) to the cabinet with two self tapping screws (not included), through the flange. : It is recommended that the two self tapping screws are secured on each end NOTE behind the cabinet face retainer, into the narrow extrusion, to hide the screws.
  • Page 8: Temperature Sensor Installation

    TEMPERATURE SENSOR INSTALLATION Some of the ML+ come equipped with a temperature sensor option that will allow the ML+ to read and display the temperature. The sensor will be attached next to the power supply on the backside of the ML+. MASTER ML+ (Backside) : In a MASTER/SLAVE Configuration, the temperature sensor on the MASTER NOTE...
  • Page 9 TEMPERATURE SENSOR INSTALLATION (continued) 3) Mount the temperature sensor on the bottom of the cabinet and tuck the excess line back up into the cabinet. NOTE : It is recommended the hole under the cabinet for the temperature line be sealed with a sealing product such as silicone.
  • Page 10: Customer Service - Warranty

    CUSTOMER SERVICE TECHNICAL SUPPORT Available 7:30 am – 4:30pm PST Phone (714) 668-9988 Email: support@pro-lite.com Web: www.pro-lite.com LIMITED WARRANTY PRO-LITE INC. Warranty to the original consumer that each of its PRO-LITE products and all components therein contained will be free from defects in materials and/or workmanship for three years from the date of purchase except those items specified herein under.