2.11 Emissions

NOx (max-min)
CO (max-min)
CO
(max-min)
2
CO/CO
ratio (max)
2
CO/CO
ratio (min)
2
Ref. Condition 15 °C, 1013,25 mbar, dry gas
NOTE: L.P.G. data refer to section 10
2.12 Range rated (parameter 23)
Input
3,8 kW
6 kW
8 kW
10 kW
12 kW
14 kW
16 kW
18 kW
20 kW
22 kW
24 kW
26 kW
28 kW
30 kW
Seasonal space heating energy efficiency class
Parameter
Rated heat output
For boiler space heaters and boiler combination heaters: useful heat
output
At rated heat output and high-temperature
regime (*)
At 30% of rated heat output and low-tem-
perature regime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
For combination heaters:
Declared load profile
Daily electricity consumption
Annual electricity consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater
inlet).

2.13 PUMP DUTY

Linea ONE boilers are fitted with a variable speed circulation unit
that is already connected up in terms of plumbing and electrics, and
the usable performance it provides is shown in the graph.
The boilers are fitted with an anti-blocking system that starts an
operating cycle every 24 hours when not used, irrespective of the
position of the function selector.
The "anti-blocking" function is only active when the electrical power
supply to the boiler is on.
Operating the circulation system without any water is strictly forbid-
den.
fan speed (rpm)
1200
1750
2050
2300
2600
2850
3100
3350
3650
3850
4150
4400
4650
5000
A
Water heating energy efficiency class
Symbol
Value
Unit
Parameter
Seasonal space heating
Prated
29
kW
energy efficiency
For boiler space heaters and boiler combination heaters: useful efficiency
At rated heat output and high-temperature
P4
29,3
kW
regime (*)
At 30% of rated heat output and low-tem-
P1
9,8
kW
perature regime (**)
Other parameters
elmax
44,0
W
Stand-by heat loss
elmin
18,5
W
Pilot flame energy consumption
PSB
7,6
W
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
XL
Water heating energy efficiency
Qelec
0,290
kWh
Daily fuel consumption
AEC
64
kWh
Annual fuel consumption
Linea ONE
30 - 15 p.p.m.
150 - 10 p.p.m.
9,0 - 9,5 %
0,0017 to 1
0,0001 to 1
CO (ppm) - less than
VARIABLE SPEED CIRCULATION UNIT
The modulating circulating function is only active for the heating func-
tion. When switching the three ways on the plate heat exchanger,
the circulation unit is set at maximum speed. The modulating
circulation function applies only to the boiler circulation unit and
not to circulation units on any external devices connected to it (e.g.
booster circulation unit).
Any of 4 operating modes can be chosen, depending on situations
and the type of plant.
By accessing parameter 90 in the technical menu, one of the fol-
lowing possibilities can be chosen:
10
20
28
35
45
55
65
75
85
97
108
120
130
150
A
Symbol
Value
Unit
ηs
93
%
η4
88,2
%
η1
98,2
%
Pstby
44,0
W
Pign
-
W
QHE
51
GJ
LWA
55
dB
mg/
NOx
19
kWh
ηwh
83
%
Qfuel
23,070
kWh
AFC
17
GJ
5