OWNER'S MANUAL Industrial Electrostatic Air Cleaner l SMOG-HOG MSH Model...
Page 2
Should you need assistance, call the United Air Specialists, Inc. customer service number shown below. To expedite your service, have the following information available when contacting UAS. UAS ORDER #: ________________________________________________________________...
SAFETY PRECAUTIONS We have provided many important safety messages in this manual on the electronic air cleaner. always read and obey all safety messages. this is the safety alert symbol. this symbol alerts you to potential hazards that can kill or hurt you and others. all safety messages will follow the safety alert symbol and the word “DANGER”, “WARNING”...
Proper use of the equipment must be collapse. When the voltage collapses, the indicator light discussed with United Air Specialists, Inc. (UAS) or your local will blink. When the overload is removed, the voltage will Representative. Operating personnel must be aware of, and automatically build up to normal and the indicator light will adhere to, the most stringent safety procedures.
SMoG-HoG ® revised 03/15 electronic air cleaner D A N G E R If the light is dim, fails to glow, or continues to flicker, the components may need cleaning or servicing (see “Cleaning Instructions”, Section 5.2 and 5.3). Do not oPerate tHiS eQuiPMent in tHe PreSence of coMBuStiBLe VAPORS OR GASES 5.
SMoG-HoG ® revised 03/15 electronic air cleaner support structure corners or the triangular insulators. time is necessary for effective cleaning. Soaking may Inspect filters, noting the condition (contaminant build seem slower and less effective than high impingement up?, media separation?, bent frames?) should not and/or hot water above 180°F for cleaning action, so have contaminant build up restricting airflow, repair or personnel should be forewarned about using excessive...
SMoG-HoG ® revised 03/15 electronic air cleaner 5.5 REPLACING DAMAGED IONIZER AUTOMATIC PARTS WASHERS WIRES certain commercially available units combine and automate the features necessary for effective cleaning, 1. remove the damaged wire from each spring. also replace including water heating, detergent injection, agitation, spring if it is damaged.
SMoG-HoG ® revised 03/15 electronic air cleaner 6.3 TROUBLESHOOTING PROCEDURE a high voltage probe is required to measure high voltages to the ionizer and collector circuits to the C A U T I O N unit. As an accessory, a high voltage probe can be purchased for a multimeter.
Page 10
SMoG-HoG ® revised 03/15 electronic air cleaner (a) Place the MSH "off", and open power pack lid door. The indicator light should be illuminated? If so, the Disconnect high voltage wire #8 to the ionizer connector unicell(s) are operational. If the indicator light is flashing with high voltage wire #7 (Collector) connected on the perform the following: power pack and place MSH "on".
Page 11
SMoG-HoG ® revised 03/15 electronic air cleaner HIGH VOLTAGE PROBE MEASUREMENTS A high voltage probe (refer to manufacturers instructions) is required to measure high voltage output from the power pack. the component door should be closed with unicell(s) installed, the indicator light illuminated and high voltage wires #8 and #7 connected to the power pack.
SMoG-HoG ® revised 03/15 electronic air cleaner 6.4 TROUBLESHOOTING TABLE ProBLeM PoSSiBLe cauSe PoSSiBLe SoLutionS 1. Control switch on, indicator lamp off, Defective lamp replace lamp air mover operates. faulty connection to lamp check connection to lamp Loss of high voltage check power supply 2.
2. Unit serial number (nameplate) 3. Part number and part description Returning parts: When returning parts directly to UAS for any reason, call UAS at 1-800-252-4647 for a return authorization number before returning the parts. this number must be on the package being returned.
Page 14
SMoG-HoG ® revised 03/15 electronic air cleaner Figure 1. unit components...
Page 15
SMoG-HoG ® revised 03/15 electronic air cleaner Figure 2. Drain Loop assembly Figure 3. Ionizer and Cell Voltage Measurement Figure 4. replacing ionizer Section Figure 5. Grounding the collector cell Section...
Page 24
UAS is limited to furnishing replacement parts F.O.B. UAS’ factory or making repairs at UAS’ factory of any parts that are determined, upon inspection by UAS, to be defective. In no event will UAS be responsible for labor or transportation charges for the removal, reshipment or reinstallation of the parts.