3.1 General Configuration

To program function settings:
1. In Programming mode, scroll using
the display.
2. Press SELECT and then
3. Press SELECT to choose the displayed option or press
saving changes.
The available options are explained in the following table.
OPTION
EXPLANATION
OUTPUT 1
Output 1 can be used as a regular detection device zone or it can be used as the output for
Arm/Disarm commands from keyfobs.
OUTPUT 2
Output 2 can be used as a regular detection device zone or it can be used as the output for Panic
alarms from keyfobs.
The LCD option determines whether the display is enabled during normal operation mode (i.e.
LCD
when the tamper is closed) or during programming mode only (disabled).
Transmissions that are out of synchronization are rejected by the receiver. Re-synchronization of
RESYNC
the transmitter with the receiver restores normal operation.
The system is able to detect RF Jamming that is usually caused by an intruder attempting to
JAMMING
compromise the security system. Jamming detecting function can be set to European (EU), United
States (US) standards, or it can be disabled.
The transmitters send a supervision signal approximately one hour after their last transmission. If
the receiver does not receive supervision signals from a specific transmitter, that transmitter is
SV TIME
regarded as inactive. Supervision time is the amount of time after which a transmitter is considered
inactive. You can program a supervision time between 2 - 24 hours.. .
3.1.1 Output Configuration
You can program the output settings of zones 1 & 2 to react to detector alarms or commands from keyfobs:
To configure Output 1
1. In Programming mode, scroll using the
the display.
2. Press SELECT; CONFIG, OUTPUT 1 appears on the display.
3. Press SELECT and use the
The following options are available:
ZONE 1 – The output is used as a regular zone output.
ARM/DIS – The output reacts to arm and disarm transmissions from 4-button keyfobs
(EL-2614). There are two relay operation modes available for Arm/Disarm. To choose the
Arm/Disarm mode, press SELECT and use the
the following modes.
STEADY – intended for use with arm/disarm inputs designed for latching key-
switches (i.e. the relay opens to arm and closes to disarm the control panel).
PULSE – intended for use with arm/disarm inputs designed for momentary key-
switches (i.e. the relay opens then closes to arm or disarm the control panel).
4. Press SELECT.
To configure Output 2
1. In Programming mode, scroll using
display.
2. Press SELECT and then
3. Press SELECT and use the
navigation keys until the MAIN, CONFIG appears on
or
or
to view the options.
Table 2: Configuration Options
and
and navigation keys to choose the required output type for Output 1.
navigation keys until MAIN, CONFIG appears on the
or
or ; CONFIG, OUTPUT 2 appears on the display.
and navigation keys to choose the required output type for Output 2.