Trotec PV4-MID-PS Operating Manual

Multiple socket outlet

Advertisement

Quick Links

PV4-MID-PS
EN
OPERATING MANUAL
MULTIPLE SOCKET OUTLET

Advertisement

Table of Contents
loading

Summary of Contents for Trotec PV4-MID-PS

  • Page 1 PV4-MID-PS OPERATING MANUAL MULTIPLE SOCKET OUTLET...
  • Page 2: Table Of Contents

    • Insert the CEE plug into a properly secured CEE socket. • Observe the following safety rules when performing work on the electrical equipment: 1. De-energise, 2. Secure against restart, 3. Verify de-energised state, 4. Earth and short-circuit, 5. Cover or fence off live parts. multiple socket outlet PV4-MID-PS...
  • Page 3 When operating the device on construction or installation sites at sockets of the building's site with unknown protective measures, a BGI608-compliant plug adapter must be used. Only qualified electricians are allowed to perform repair work on the multiple socket outlet. multiple socket outlet PV4-MID-PS...
  • Page 4: Information About The Device

    Have loose or defective mounting sockets replaced by plugging of an additional consumer to the PV4-MID PS. a qualified electrician. For sealing the sockets, use the Trotec pull-up seals (numbered consecutively). The seals can prevent manipulations. You can Warning of electrical voltage...
  • Page 5 Pulse value in kWh (metrological LED) MID-compliant energy meter Min./reference current (max. continuous current) Nominal voltage/ frequency Connection diagram (1 phase and neutral conductor) Type of protection Serial number MID designation Homologation number Accuracy class Operating temperature range multiple socket outlet PV4-MID-PS...
  • Page 6 Starting current Ist 20 mA Accuracy Active energy class B EN 50470-3 (MID) according to Active energy class 1 EN 62053-21 (NO MID) according to Reactive energy class 2 EN 62053-23 according to S0 output Passive optoisolated Max. values (according to 27 V DC – 27 mA directive EN 602053-31) multiple socket outlet PV4-MID-PS...
  • Page 7: Transport And Storage

    • Do not cover the device. • The storage temperature is the same as the range given in • Do not place any further objects on the device. the Technical data chapter. • Insert the CEE plug into a properly secured socket. multiple socket outlet PV4-MID-PS...
  • Page 8: Operation

    ð If this is the case, tighten the seal cable or repeat steps 1–7. ð If you cannot open the safety socket (5) any longer or if the plug cannot be pulled out, the safety socket (5) is secured. multiple socket outlet PV4-MID-PS...
  • Page 9 KVAh, ■ ■ counter kvarh Other information Icon Status Display Port Partial counter/ status start/ ● ● stop S0 output status active ● Metrological error Code XX - ● ● display. Non-usable meter, return to manufacturer multiple socket outlet PV4-MID-PS...
  • Page 10 3. Once you have reached the last partial counter page, press the multifunction button (16) to exit the area for the partial Leistungsfaktor counter again. ð The total counter page will be displayed. Frequenz Zugang / Einstellungen Ansicht kann ggf. Messtechnischer abweichen Firmwarebestand Messtechnische Prüfsumme multiple socket outlet PV4-MID-PS...
  • Page 11 ð Once the Stop sequence is completely indicated, the partial counter will be stopped. The symbol will be displayed. ð If you let go of the multifunction button (16) during the 3 s, the partial counter will not be stopped. multiple socket outlet PV4-MID-PS...
  • Page 12: Cleaning

    T (2), switch the residual current device (7) back on again and connect the device to the multiple socket outlet. If the residual current device (7) then trips again, take the device out of operation and have it checked by a qualified electrician. multiple socket outlet PV4-MID-PS...
  • Page 13: Maintenance

    Maintenance administration. For further return options provided by us please refer to our website https://de.trotec.com/shop/. Visual inspection The separate collection of waste electrical and electronic Check the device for external damage before every start-up.
  • Page 14 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...