10.
Maintenance and repair
Observe the instructions in section 3, "Safety instructions", and in section 9, "Faults, causes and remedy"!
For information on maintenance of a hydraulic motor, refer to the operating instructions for the
hydraulic motor.
10.1
General notes on maintenance
All maintenance and repair work must be done with care and by duly trained and qualified personnel only.
The following applies to all work in item 10.2:
Switch the gear unit and addon components off.
Secure the drive unit to prevent it from being started up unintentionally.
Attach a warning notice to the start switch!
The periods indicated in table 12 depend on the conditions under which the gear unit
is operated. Only average periods can therefore be stated here. These refer to:
The operator must ensure that the intervals stated in table 12 are adhered to.
This also applies if the maintenance work is included in the operator's internal
maintenance schedules.
Table 12: Maintenance and repair work
Measures
Checking oil temperature
Checking for unusual gearunit
noise
Checking oil level
Checking gear unit for leaks
Test the water content of the oil
Perform the first oil change
Performing subsequent oil changes
Clean the air filter or breather screw
Refilling Taconite seals with grease
a daily operating time of
a duty factor "ED" of
Operating temperature of 90°C (applies to mineral oil)
Daily
Daily
Monthly
Monthly
After approx. 400 operating hours
after startup, at least once per year
Approx. 400 operating hours
following startup
Every 18 months or
5000 operating hours
Every 3 months
Every 3000 operating hours or
every 6 months at least
BA 9213 en 03/2012
44 / 55
24
h
100 %
100 °C (applies to synthetic oil)
Periods
‐ Middle of the oil sight glass
Middle of the markings on
Upper mark
see item 10.1.1
see item 10.2.2
see item 10.2.2
1)
see item 10.2.3
or item 10.2.4
see item 10.2.6
Remarks
the angular oil level
indicator
on the oil dipstick