Fitting; General Information On Fitting - Siemens FLENDER PLANUREX 2 PBUC Series Assembly And Operating Instructions Manual

Planetary gear unit type for bucket wheel drives
Table of Contents

Advertisement

6.

Fitting

Observe the instructions in section 3, "Safety instructions"!
6.1

General information on fitting

When transporting the gear unit observe the notes in section 4.
Fitting work must be done with great care by authorised, trained and qualified personnel. The manufacturer
cannot be held liable for damage caused by incorrect assembly and installation.
During the planning phase sufficient space must be allowed around the gear unit for later care and
maintenance work.
Free convection through the surface of the housing must be ensured by suitable measures.
Adequate lifting equipment must be available before beginning the fitting work.
During operation the unit must not be allowed to heat up through exposure to heat
from external sources such as sunlight, and suitable measures must be taken to
prevent this!
Such measures may be:
­ fitting a sunshade roof
or
­ fitting an additional cooling unit
or
­ fitting the oil sump with a temperature-monitoring device with a cut­out function.
If a sunshade roof is fitted, heat must be prevented from building up!
If a temperature monitoring device is fitted, a warning signal must be emitted when the
maximum permitted oil­sump temperature is reached. If the maximum permitted
oil­sump temperature is exceeded, the drive must be shut off.
Such shutting off may cause the operator's system to stop!
The operator should ensure that no foreign bodies affect the proper function of the
gear unit (e.g. falling objects or heaping over).
No electrical welding work must be done at all on the drive.
The drives must not be used as an earthing point for welding operations. Toothed
parts and bearings may be irreparably damaged by welding.
All the fastening points provided by the design of the unit must be used.
Screws which have been damaged during assembly or disassembly work must be
replaced with new ones of the same strength class and type.
To ensure proper lubrication during operation, the mounting position specified on the drawings
must always be observed.
BA 9213 en 03/2012