Wayne 24-Volt Backup Sump Pump ESP45 Operating And Parts Manual page 2

24-volt backup sump pump

Advertisement

Operating Instructions and Parts Manual
Battery Information
The system is designed to operate most
eye(s), flush with cold running water
efficiently with sealed lead acid (SLA)
for 10 minutes and seek immediate
batteries. Deep cycle marine batteries
medical attention. If acid contacts your
can also be used.
skin or clothing, wash immediately
Sealed lead acid batteries cost slightly
with soap and water.
more, but they can last longer. Wayne
offers a 40 amp hour battery WSB1240
and a 75 amp hour battery WSB1275.
flame in the vicinity of the battery.
The oversize battery case (included) will
accommodate two 12-volt SLA batteries
or two 12-volt deep cycle marine batteries
battery posts because they may spark or
short-circuit the system or battery,
(up to a 27-frame size).
causing an explosion.
Retain blue foam pad to support Wayne
sealed lead-acid batteries. Use new,
PS/BC Features
identical batteries (from the same
manufacturer and of the same capacity).
POWER CIRCUITS:
When batteries wear out replace them as
• Power Supply/Battery Charger (PS/BC)
a set. Chart 1 illustrates the expected
monitors power availability and
performance with various battery
automatically switches to battery
combinations. Do not use batteries rated
operation during power outage.
• Charger will run pump motor or charge
below 40 amp hours.
batteries when plugged into AC power
Be certain that the area around the
• Automatically charges the batteries
batteries is well ventilated. Before
• Operates on 120 VAC and 24 VDC
servicing the batteries, blow away
(Using 2 batteries)
gasses by waving a piece of cardboard
• The PS/BC can be left connected to
near the batteries.
the batteries indefinitely
Dangerous
• The PS/BC is designed for the Wayne
hydrogen gas can
be released from batteries while
Water Systems pump only, DO NOT
charging. Sparks can ignite the gas in
Use For Any Other Purpose
an enclosed space. Wear safety goggles
when connecting batteries. Battery
connections should be made in a well-
ventilated area.
Working in the
vicinity of lead acid
batteries can be dangerous. Before
making connections or servicing the
batteries, read and follow instructions in
all applicable instruction manuals. To
reduce the risk of battery explosion,
follow the instructions in this manual
and those published by the battery
manufacturer, as well as those of any
other equipment used in the
surrounding area.
An assistant should be present or close
enough to come to your aid in the
event of an emergency. Have a reliable
source of fresh water and soap nearby
in case battery acid contacts clothing,
skin or eyes.
Wear eye and clothing protection when
working around lead acid batteries.
Avoid touching your eyes when
Figure 1 - Battery connection: two 12-volt batteries equals a 24-volt battery
working around lead acid batteries.
www.waynepumps.com
CHART 1 - STANDBY POWER
If battery acid
contacts your
PUMPING CAPACITY
Amp Hours
Per Battery
40.0
80.0
120.0
Never smoke or
* Assumes the sump pump is lifting water 10'
allow a spark or
SYSTEM WILL ALARM IF:
Avoid dropping
• You will hear a beeping alarm if
metal tools on the
pump motor is running
• You will hear a continuous alarm if the
pump fuse on front panel is blown
• You will hear a continuous alarm if
the battery voltage drops below 21.6
NOTE: The alarm must be on for the
mute function to activate.
LIGHTS:
• Green Light indicates AC power is
available
• Yellow Light indicates battery is
connected correctly
• Red Light is on when battery voltage
is low or if the pump motor fuse on
the front panel is blown
PUMP:
• The pump will turn on when the
float switch rises. The pump motor
will keep running for 15 seconds
after the float drops
(Black)
Negative
Battery Cable
(Red)
Positive Battery Cable
Jumper Wire
2
For Replacement Parts, call 1-800-237-0987
Total Gallons
Please provide following information:
Pumped*
-Model number
11,000
-Serial number (if any)
22,000
-Part descriptions and number as shown in parts list
33,000
1
PS/BC
Address parts correspondence to:
Wayne Water Systems
101 Production Drive
Harrison, OH 45030 U.S.A.
7
Ref.
6
No. Description
1
Pump
2
PS/BC (power supply/ battery charger)
3
Impeller assembly
5
4
Wear ring
5
Impeller plate
6
Seal
*7
Float Kit, ESP45
4
* Service Part Only
3
7
ESP45
2
Part
Number
Qty.
06710
1
30260-001
1
29884-001
1
28183-001
1
15958
1
21203-001
1
60120-001
1
www.waynepumps.com