Zone code:
Ex II 2 G T4
EX
II
2
G
T4
2.4. Safety Instructions
Technical condition
■ Check the SATA clean RCS units for proper function and leakage be-
fore each use.
■ Never operate the SATA clean RCS units if damaged or if parts are
missing.
■ Check the SATA clean RCS units before each use and repair if necessary.
■ In case of damage to the SATA clean RCS units, immediately discontin-
ue use and disconnect from compressed air circuit.
■ Never make unauthorized alterations or technical modifications to the SATA
clean RCS units.
Cleaning media
■ Never use cleaning media containing acid, lye or gasoline.
■ Never use halogenated hydrocarbon based cleaning media.
Connected components
■ Use only genuine SATA replacement parts or accessories.
■ The connected hoses and lines must reliably withstand the expected
thermal, chemical and mechanical load requirements.
■ Disconnecting pressurized hoses can cause them to move in a whip-
like manner, resulting in injuries. Always bleed the hoses completely
before removal.
Installation site
■ When installing the SATA clean RCS units outside the spray booth and
solvent-based cleaning liquids are in use, the following is required:
■ Ex-Zone 1 with a radius of 8' 2" around the device.
■ Ex-Zone 2 with a radius of 8' 2" to 16' 5" around the device.
■ Never use SATA clean RCS units in areas near ignition sources, such
as open flames, burning cigarettes or electrical equipment that is not
explosion proof.
Operating Instructions for SATA RCS
EX sign
Equipment category
Device category
Gas category
Temperature classification
US