Mitsubishi Electric MSZ-LN-VG Series Service Manual page 108

Outdoor unit hfc utilized r32
Table of Contents

Advertisement

Part name
Linear expansion valve
WHT
RED
LEV
ORN
YLW
BLU
High pressure switch (HPS)
MXZ-3F54VF/3F68VF/4F72VF
MXZ-3F54VF2/3F68VF2/4F72VF2/4F80VF2
MXZ-3F54VF3/3F68VF3/4F72VF3/4F80VF3
Defrost heater
MXZ-2F53VFH
MXZ-2F53VFH2
MXZ-2F53VFH3
OBH790D
Measure the resistance with a tester. (Part temperature : -10°C - 40°C)
Color of lead wire
WHT - RED
RED - ORN
YLW - RED
RED - BLU
Pressure
3.43 ± 0.15 MPa
HPS
4.14 ± 0.1 MPa
Measure the resistance with a tester. (Part temperature : -10°C - 40°C)
Normal
349
- 428
108
Check method and criterion
Normal
37.4
- 53.9
Normal
Close
Open

Hide quick links: