Junction box

Advertisement

7
Grounding
Attach the crimp-on lug (FV2-4 BLU, supplied) to the ground wire (IV-2sq., local supply), then fix it to the ground
terminal.
8
Wiring for MC-3000S-N
Connect the external equipment to the MC-3000S-N, using the TTYCSLA and FR-FTPC-CY cables.
1.
Fabricate the TTYCSLA and FR-FTPC-CY cables as shown below.
TTYCSLA cable
Aluminum tape
Sheath
Sheath
Armor
Vinyl tape (Width: 20 mm)
FR-FTPC-CY cable
Cable jacket
2.
Unfasten seven binding screws (M4×10) to remove the junction box cover.
60 mm
5 mm
Drain wire
Drain wire
600 mm
Pass the heat shrink tubing (local supply)
onto the drain wire, then attach the crimp-on
lug (FV1.25-4 (LF) RED, supplied) to it.
Crimp-on lug
Inner sheath
500 mm
6 mm
0.5 to 1 mm
Crimp the rod terminals (AI 0,75-6
GY, supplied), using the crimping
tool (CRIMPFOX 10S). After crimp-
ing, confirm that the 0.5 to 1 mm of
the wires are exposed.
LAN connector
7
Ground
Ground
terminal
terminal
Ground wire
Ground wire