Junction box

Advertisement

TTYCSLA cable (for MC-3010A-N)
Aluminum tape
Sheath
Sheath
Armor
Vinyl tape (Width: 20 mm)
The length of "L"
D
E
C
F
B
A
2.
Unfasten seven binding screws (M4×10) to remove the junction box cover.
3.
Release the internal wiring cables from the wire saddles.
4.
Slightly loosen two binding screws (M4×10) to pull out the fixing plate.
Note: Loosen the binding screws only enough to pull out the fixing plate. If the screws are loosened too much,
the plate may fall and be damaged when it is hung in the next step.
60 mm
5 mm
Drain wire
Drain wire
L
Pass the heat shrink tubing (local supply)
onto the drain wire, then attach the crimp-on
lug (FV1.25-4 (LF) RED, supplied) to it.
Crimp-on lug
Front
Location
B
C
D
E
F
Wire saddle
Wire saddle
6 mm
0.5 to 1 mm
Crimp the rod terminals (AI 0,75-6
GY, supplied), using the crimping tool
(CRIMPFOX 10S). After crimping,
confirm that the 0.5 to 1 mm of the
The length of "L"
900 mm
900 mm
1000 mm