Download Print this page

Furuno IF-8540 Installation Instructions Manual page 11

Junction box

Advertisement

5.
Hang the plate to the screws loosened at step 4.
The figure below is an example for hanging the second fixing plate from the top.
Fixing plate
Fixing plate
6.
Unfasten four binding screws (M4×10) to remove the sensor adapter cover.
7.
Pass the cables through the cable entrance, then fix the cables to the cable clamp with a cable ties (local sup-
ply).
Note 1: The armor of the cable should contact the cable clamp.
Note 2: The fixing locations for the cables are not specified. However, see the figure below for reference.
7
4
3
8.
Attach a cable band (supplied) to each cable to be connected to the junction box and record sensor name/equip-
ment name on each cable band.
9.
Fix the drain wires of the TTYCSLA cables to the locations in-
dicated in the figure to the right.
Fixing screws for the drain wires are preattached to the unit.
10. Connect the cables to respective connectors on the sensor
adapter, referring to the interconnection diagram at the middle
of this document and the sticker attached to the rear side of
the sensor adapter cover.
11. Reattach the sensor adapter cover and replace the fixing
plate to the original location.
12. Fasten two binding screws loosened at step 4.
13. Fix the internal wiring cable released at step 3 with the wire saddle.
14. Bundle the cables with the wiring duct and fix them with the CKS clamp.
15. Reattach the junction box cover.
Unfasten these binding screws
Unfasten these binding screws
to pull out the fixing plate.
to pull out the fixing plate.
6
2
1
5
Wiring duct
Wiring duct
No.
Cable
1
FR-FTPC-CY
2
TTYCSLA-1Q
3
TTYCSLA-4
4
TTYCSLA-1
5
DPYC-1.5
6
MPYC-12
7
TTYCSLA-1
CKS clamp
CKS clamp
11
Access point
MC-3000S-N
J1 port (IF-8540)
MC-3020D-N
MC-3010A-N
: Fixing locations for the drain wires
: Fixing locations for the drain wires

Advertisement

loading