Download Print this page

Furuno IF-8540 Installation Instructions Manual page 4

Junction box

Advertisement

4.
Hang the plate to the screws loosened at step 3.
The figure below is an example for the first additional unit.
Fixing plate
Fixing plate
5.
Unfasten four binding screws (M4×10) to remove the additional sensor adapter cover.
6.
Fix the unit to the fixing plate with four binding screws (M4×10, supplied with sensor adapter).
7.
Connect the optional cable assy. (AI.14-8AI.34-6L1000) between sensor adapters.
The internal wiring between sensor adapters in the junction box is as shown in the figure below.
MC-3020D-N
J1
J2
MC-3020D-N
J1
J2
MC-3020D-N
J1
J1
8.
See "8. Wiring for MC-3000S-N" (page 7) and "9. Wiring for MC-3020D-N and MC-3010A-N" (page 9) to connect
the cable from the external equipment to the sensor adapter.
9.
See "5-2. Setting the Termination Resistor and Modbus Address" (page 5) to set the termination resistor and
Modbus address.
Unfasten these binding screws
Unfasten these binding screws
to pull out the fixing plate.
to pull out the fixing plate.
Binding screw
Binding screw
(4 pcs)
(4 pcs)
First additional unit*
J2
J1
Second additional unit*
MC-3000S-N
J2
Sensor adapter
Sensor adapter
(MC-3010A-N or
(MC-3010A-N or
MC-3020D-N
MC-3020D-N
Front
J2
J1
*: The unit may be pre-installed and the internal
wiring completed depending on the configuration
purchased.
J1
24 VDC
4

Advertisement