18 | English
Technical Data
Digital angle and grade measuring device
Article number
"HOLD" Function
"Simple mitre" operating mode
"Compound mitre" operating mode
"Grade measurement" operating mode
Display illumination
Calibration
Measuring range of angle measurement
Measuring accuracy of angles
Smallest display unit
Measuring range of grade measurement
Accuracy of grade measurement
– 0°/90°
– 1°–89°
A)
Laser working range
Vertical levelling accuracy of laser
Horizontal levelling accuracy of laser
Clearance of laser exit – bottom edge of measur-
ing tool
Operating temperature
Storage temperature
Max. altitude
Relative air humidity max.
Pollution degree according to IEC 61010-1
Laser class
Laser type
C
6
Laser point divergence
Batteries
Rechargeable batteries
Approx. operating duration (alkali-manganese
C)
batteries)
Automatic switch-off after approx.
Leg length
Weight according to
EPTA-Procedure 01:2014
Dimensions (length × width × height)
IP 54 (dust and splash-proof)
A) The working range may be reduced by unfavourable environmental conditions
(e.g. direct sunlight).
B) Only non-conductive deposits occur, whereby occasional temporary conductivity
caused by condensation is expected.
C) Operating duration without laser
The serial number (13) on the type plate is used to clearly identify your measuring tool.
Assembly
Inserting/Replacing Batteries (see figure A)
It is recommended that you use alkaline manganese batteries to operate the
measuring tool.
To open the battery compartment cover (5), press the locking mechan-
ism (6) and fold the battery compartment cover up. Insert the batteries/re-
chargeable batteries.
When doing so, ensure that the polarity is correct and corresponds to the
diagram on the battery compartment cover.
Battery Indicator
The battery indicator (b) always indicates the current battery status:
Indicator Capacity
90–100 %
60–90 %
30–60 %
10–30 %
0–10 %
The empty battery indicator flashes. You can measure for ap-
proximately another 15–20 min from when the flashing begins
until the tool shuts down.
Always replace all the batteries at the same time. Only use batteries from the
same manufacturer and which have the same capacity.
1 609 92A 58L | (22.11.2019)
GAM 270 MFL
3 601 K76 400
0° to 270°
±0.1°
0.1°
0–360° (4 × 90°)
±0.05°
±0.1°
30 m
±0.5 mm/m
±1 mm/m
30 mm
−10 °C to +50 °C
−20 °C to +70 °C
2000 m
90 %
B)
2
2
650 nm, < 1 mW
1
0.6 mrad (full angle)
4 × 1.5 V LR6 (AA)
4 × 1.2 V HR6 (AA)
50 h
30 min
600 mm
1.7 kg
684 × 52 × 60 mm
Bosch Power Tools

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents