Daewoo KUS-T24HBR Manual page 10

Table of Contents

Advertisement

4-3. Refrigerator temperature control
1. REF. SET
2. Refrigerator Temperature Sensor
1. By pressing the 'REF. SET' button.
8 (Min), 7, 6, 5, 4 (Medium), 3, 2, 1, 0 (Max)
2. Compressor & Refrigerator Cooling Fan controlled by each dial ON/OFF point.
3. Refrigerator compartment ON/OFF diff is 0.5 degree.
- Refrigerator 'Middle' OFF point is 0.7 degree.
- If RT <= 13 degree, Freezer 'Middle' OFF point is 2.7 degree. ( 2 degree up )
4. Freezer Step Diff is 1 degree.
( but 8 -> 7 step is 2 degree and 1 -> 0 step is 0.5 degree )
5. Weak Refrigeration.
- When sensing weak refrigeration, compressor is ON without Freezer sensing point.
- When Refrigerator sensor reaches sensor Off point, compressor depends upon Freezer sensor.
- Weak Refrigeration sensing ON point : Each dial Off point + 7 degree.
- Weak Refrigeration sensing Off point : same as each dial Off point.
6. Control point at each dial ( Refrigerator sensing point )
Division
Setting
temperature
Temperature
Control
Sensor
On
Normal
Sensor
Off
Sensor
On
RT <= 13C
Sensor
Off
Weak
Sensor
On
Refrigeration
Step Diff
7. Super cool (QUICK)
- For 40 min.
- Refrigerator cooling fan & Compressor is ON until Refrigerator sensing -7 degree.
- Inter Cooler fan is ON for 10 min. ( When Door opens Inter cooler is off, the remaining time will go on.)
- During QUICK mode the dial setting is same as Max ( 0 degree)
- After 40 min (QUICK mode) the dial changes into Medium ( 4 degree).
INPUT
Initially
1st
2nd
On
Press
Press
4
3
2
Medium
Medium Max
1.2
0.2
-0.8
0.7
-0.3
-1.3
3.2
2.2
1.2
2.7
1.7
0.7
7.7
6.7
5.7
1 degree
1. Compressor
2. Refrigerator Cooling Fan
CONTENTS
3rd
4th
5th
Press
Press
Press
1
0
QUICK
Max
QUICK
-1.8
-3.8
-2.3
-4.3
0.2
-1.8
-
-0.3
-2.3
4.7
2.7
0.5 degree
10
CONTROL OBJECT
6th
7th
8th
Press
Press
Press
8
7
Min
Medium Min
6.2
4.2
3.2
4.2
3.7
2.7
8.2
6.2
5.2
6.2
5.7
4.7
11.2
10.7
9.7
2 degree
9th
Press
6
5
2.2
1.7
4.2
3.7
8.7
1 degree

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kus-t24hbgKus-t24hbsFrs-t24bbFrs-t24hb

Table of Contents