Hoover Vibra brush 5841 Manual

Hoover Vibra brush 5841 Manual

Carpet shampooer with vibrating powerbrush

Advertisement

Carpet Shampooer with
Vibrating Powerbrush
vibra brush

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vibra brush 5841 and is the answer not in the manual?

Questions and answers

Tama davis
May 18, 2025

Need a suction. Inlet knozzle

1 comments:
Mr. Anderson
May 23, 2025

The suction inlet nozzle on the Hoover Vibra Brush 5841 is a removable part located under the Hose Connection Lid. It is responsible for collecting dirty water and cleaning solution from surfaces during use. It can be removed and cleaned using lukewarm water to maintain performance.

This answer is automatically generated

Larraine
February 15, 2025

Why won’t water come out of spot cleaner hose

1 comments:
Mr. Anderson
February 15, 2025

Water may not come out of the Hoover Vibra Brush 5841 spot cleaner hose due to the following reasons:

1. The Clean Water Tank may be empty. Refill it if necessary.
2. The Hose Connection Lid may not be securely closed. Ensure it clicks into place.
3. The Spot Cleaner attachment may not be properly inserted. Reattach it correctly.
4. The trigger may not be pressed correctly. Press the Spot Cleaner Trigger Release firmly.
5. There may be a blockage in the hose or nozzle. Check and clean them if needed.

Ensure these steps are followed to restore proper water flow.

This answer is automatically generated

David Ross
March 28, 2025

Availability of short coil hose for dirty water tank (Hoover brush carpet shampooer model 5481). Regards David (Bendigo VIC)

User image 67e62b5f5d682
Rhonda Taylor
January 20, 2025

I need a new clean water tank. Can you tell me where i can purchase one & how much.

Summary of Contents for Hoover Vibra brush 5841

  • Page 1 Carpet Shampooer with Vibrating Powerbrush vibra brush...
  • Page 3 5841 Vibra Brush Congratulations on the purchase of your new HOOVER carpet shampooer. There are many useful features built into your carpet shampooer. We recommend that you carefully read this instruction manual to take the best advantage of these features.
  • Page 4: Before You Begin

    Before You Begin The cleaner must be operated in accordance with these instructions and used only for domestic household cleaning. This will ensure you obtain full benefit from your new cleaner. This cleaner is not fit to be used as an industrial cleaner and will void the manufacturer’s warranty if used inappropriately.
  • Page 5: Safety Precautions And Warnings

    Safety Precautions & Warnings IMPORTANT! Always ensure that the shampooer is switched off and that the power plug is disconnected from the power supply before cleaning your shampooer, when not in use, or attempting any maintenance task. WARNING! The cleaner must only be connected to an AC power supply at the voltage shown on the rating plate.
  • Page 6 Safety Precautions & Warnings FAULTS Caution! Consult the trouble shooting guide in this manual if The cleaning head contains electrical connection. your carpet shampooer fails to operate properly. The cleaning head is not a serviceable part. Please return the product to your nearest Godfreys store if Do not continue to use this shampooer if it appears the cleaning head is faulty.
  • Page 7 Assembling IMPORTANT! Always remove the power plug from the power supply before fitting or removing accessories! Remove the two screws from the handle insert, as shown. Insert the handle into the body of the shampooer ensuring that the handle is pointing backwards. Secure into place with the screws provided.
  • Page 8: Preparing The Carpet

    Preparing the Carpet IMPORTANT! Do not use the shampooer as a dry vacuum. Preparation Check for Colour Fastness Vacuum carpeted surfaces thoroughly. Use Before you begin cleaning the carpet, test for colour a vacuum cleaner with a powerbrush for best fastness.
  • Page 9 Instructions For Use IMPORTANT! Never leave the shampooer unattended with the power switched on. Turn off the shampooer and disconnect the power cord from the power supply before emptying and filling the tanks. Do not oversaturate the carpet. WARNING! Do not use bleach. Damage to the shampooer will result. Only use the manufacturer’s recommended solution.
  • Page 10 Instructions For Use (continued) Plug the power plug into the power supply. Turn on the shampooer by pressing the On/Off Button located on the base of the shampooer. IMPORTANT! Ensure that the power cord is secured into the Cable Hock, as shown. Step onto the Handle Release Pedal to put the shampooer into the cleaning position.
  • Page 11 Instructions For Use (continued) WARNING! When the Dirty Water Tank is full, the shampooer will make an abnormal noise and the suction will cease. Switch off the shampooer and empty the Dirty Water Tank. Dirty Water Tank When the dirty water tank is full, lock the shampooer in the upright position, turn off the shampooer and remove the power plug from the power supply.
  • Page 12 Instructions For Use (continued) Using the Spot Cleaner IMPORTANT! Always remove the power plug from the power socket before fitting or removing accessories. Assembly Ensure that the cleaner is secured in the upright position. Lift the Hose Connection Lid on the base of the shampooer. Insert the Spot Cleaner attachment as shown.
  • Page 13: Maintenance

    Maintenance IMPORTANT! Always remove the power plug from the power socket before performing any maintenance. Cleaning or Replacing the Suction Inlet Nozzle Lift the Hose Connection Lid. Gently remove the Suction Inlet Nozzle, as shown. The nozzle can be cleaned using lukewarm water. Cleaning or Replacing the Vibrating Powerbrush Remove both the Dirty Water Tank &...
  • Page 14: Troubleshooting

    Troubleshooting Problems and Solutions If you come across a problem, please use this checklist before contacting Hoover Customer Care on AUS: 1300 360 845, NZ: 0800 387 442. Fault Solutions Reduced spray or no Refill the Clean Water Tank with water and solution.
  • Page 15: Customer Care

    Customer Care Please contact Hoover Customer Care: 1300 360 845 (AUS) 0800 387 442 (NZ) to find your local spare parts provider. Description Product Code Dirty Water Tank 33155674 Clean Water Tank 33155675 Suction Inlet Nozzle 31155387 Replacement Powerbrush 31155388...
  • Page 16 1300 360 845, Monday-Friday 9am-5pm EST. The decision New Zealand 0800 387 442 to repair or replace the cleaner is at the sole discretion of Hoover Floorcare. If Hoover Floorcare decide to repair or replace the cleaner, To find out more about our range, it will do so at its own cost.