I
NTSC 4.43MHz COLOR DEMODULATION
ADJUSTME~T(RV108,RV112,RV103,RV106)
I.
NTSC4.43MHz-
COLOR adjustment (RV 108,RVJ 12)
(I) Receive NTSC 4.43 color bar signal (75% color bar).
(2) ConneCt an oscilloscope to 1Cl24 pin-@ (B-OUT).
(3) AdjustRV108 (443NT-COL) so that waveform peaks should have
thesamelevel(mostflat),
(B-OUT)
(Adjust so that the first and t~e 4th
peaks should ha Ye the same level.)
f
J1hmthancpp
(4) When cyan and magenta have level difference, adjust RVl 12
(443NT-HUE)andRV108(443NT-COL)alternativelytoremove,
by tracking.
(B-OUT}
When cyan and magenta have
level difference, adjust RV112
and RV108 alternatively to remove.
2.
NTSC 4.43MHz- COLOR (R-Y) adjustment (RV103, RV106)
(1) Receive theNTSC4.43 color bar signal (75%,chromacolorbar).
(2) Connect an oscilloscope to the Q127 emitter (R-Y OUT), and
adjust RVI03(443NT-SH!FT)
so that the output of the burst
sec.(ion (B-Y axis signal output) becomes 0.
(3) ConnectanoscilloscopetolC124pin-@(R-OUT).AdjustRV106
(443NT-illL (R-Y))so that the level difftrn1ceshould beminimum.
(A-OUT)
less than 60mV
(Adjust for B=D. [less than 20mV] Also level difference
between Band C should be less than 60mV.}
PAL
COLOR
DEMODULATION
ADJUSTMENT
(RV113,RV2/SEP101, RV110,RV105,RV205)
I.
PAL PHASE Adjustment (RVl 13,RV2/SEP101)
(1)
Receive the special PAL color-bar.
(2) Connect a~ oscilloscope to emitter of Q127 (R-Y OUT).
(3) Adjust RV113 (PAL-PHASE) so that B-Y (0/180°) and-PAL
portion (in the R-Y demodulated output) becomes "0" (flat) as
following figure.
(R-YOUT)
The anti-PAL portion ha,s a smauCT--
level difference in every other
horizontal period. So, adjust so
that average becomes "O".
(4) Connect an oscilloscope to emitter of Ql 28 {B-Y OUT).
(5) Adjust RV2 inside SEPIOI so that R-Y (90°/90°) anti-PAL
portion (in B-Y demodulated output) becomes "O" (tlat) as following
figure.
R-Y (90°/90°)
(B-YOUT) a+ti-PALsignal
n
Fl-
The anti-PAL portion has a small
level difference in every other
horizontal period. So, adjust so
that average becomes
"O".
(
For the adjustm~nts of (3) and (5), it is also possible to set the color)
level to MAX with the chroma adjusting knob of the unit and erase