Features - Sony Trinitron PVM-5041Q Operating Instructions Manual

Color video monitor
Hide thumbs Also See for Trinitron PVM-5041Q:
Table of Contents

Advertisement

Features

Four color systems available
The monitor can display NTSC
NTSC
1)
signals. The appropriate color system is selected
4.43
automatically.
Blue only picture
The picture can be displayed in blue and black only. This
facilitates hue adjustment and the observation of video
noise.
Analog RGB/component input connectors
Analog RGB or component (Y, R-Y, and B-Y) signals from
video equipment can be input through these connectors.
Beam current feedback circuit
The built-in beam current feedback circuit assures stable
white balance.
Comb filter
When NTSC video signals are received, a comb filter
activates to increase the resolution, resulting in fine picture
detail without color spill or color noise.
Under scan 4:3/16:9 selector
The monitor can display the 16:9 signal with the correct
ratio of width and height, compressing the picture vertically.
Selecting 16:9 with the UNDER SCAN 4:3/16:9 selector on
the rear panel in the under scan mode, the ratio of the
picture will change to 16:9.
Precautions
On safety
• Operate the unit on 100 – 240 V AC (for PVM-6041QM),
120 V AC (for PVM-5041Q) or 12 V DC. For the AC
operation, use only the supplied AC power cord or the
AC power adaptor recommended (not supplied). Do not
use any other type. For the battery operation, use only
the NP-1A/1B battery pack (not supplied). Do not use any
other batteries.
• Should any liquid or solid object fall into the cabinet,
unplug the unit and have it checked by qualified
personnel before operating it further.
• Unplug the unit from the wall outlet if it is not to be used
for several days.
• To disconnect the AC power cord, pull it out by the plug.
Never pull the cord itself.
On installation
• Allow adequate air circulation to prevent internal heat
build-up. Do not place the unit on surfaces (rugs,
blankets, etc.) or near materials (curtains, draperies) that
may block the ventilation holes.
• Do not install the unit near heat sources such as
radiators or air ducts, or in a place subject to direct
sunlight, excessive dust, mechanical vibration or shock.
, PAL, SECAM and
3.58
2)
Automatic termination
(only connector marked
The VIDEO IN connector is terminated at 75 ohms inside,
when no cable is connected to the loop-through output
connectors. When a cable is connected to an output
connector, the 75-ohm termination is automatically
released.
EIA standard 19-inch rack mounting
By using an MB-520 mounting bracket (not supplied), the
monitor can be mounted in an EIA standard 19-inch rack.
For details on mounting, see the instruction manual of the
MB-520.
1) An NTSC
signal is used for playing back NTSC-recorded
4.43
video cassettes with a video tape recorder/player especially
designed for use with this system.
2) The UNDER SCAN 4:3/16:9 selector has been adopted since
the serial No. 2500001 product.
• Keep the unit away from a loudspeaker or motor, as the
picture may be affected.
• If you mount the monitor in a rack or shelf, devices
around the monitor may prevent adequate air circulation,
raising the operating temperature and possibly causing
malfunction or overheating. Take care to leave adequate
clearance around the monitor and not to block the
ventilation holes. Or install a ventilation fan to keep the
operating temperature range between 0°C and 35°C.
On cleaning
Clean the unit with a slightly dampened soft cloth. Use a
mild household detergent. Never use strong solvents such
as thinner or benzine as they might damage the finish of
the cabinet.
As a safety precaution, unplug the unit before cleaning it.
On repacking
Retain the original carton and packing materials for safe
transport of this unit in the future.
If you have any questions about this unit, contact your
authorized Sony dealer.
)
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trinitron pvm-6041qTrinitron pvm-6041qm

Table of Contents