Download Print this page

Pentair INTELLICOMM II Installation Manual page 5

Interface adaptor

Advertisement

Available languages

Available languages

5
Connection from IntelliComm II to an IntelliFlo VF or IntelliFlo VSD pump is via a 15 m RS-485 communication cable (P/N 350122),
which is included in this kit.
Note: Connect m³/h - RPM 1, 2, 3, and 4 to any control output or auxiliary relay circuit (RELAY 1-4) on the automation circuit board.
Typically, m³/h - RPM 1 connects to Filter Pump. If more than one terminal input is active, the highest input number (m³/h - RPM 4)
will take priority regardless of the pump setting.
Connecting IntelliComm® II to IntelliFlo
ControlPro connection
RS-485 COMMUNICATION
CABLE (22 AWG)
9 - 24 VDC
RED
BLK
M³/H - RPM 1
(PROGRAM 1)
M³/H - RPM 2
(PROGRAM 2)
M³/H - RPM 3
(PROGRAM 3)
M³/H - RPM 4
(PROGRAM 4)
9 - 24V DC/AC
ControlPro+ connection
RS-485 COMMUNICATION
CABLE (22 AWG)
9 - 24 VDC
RED
BLK
M³/H - RPM 1
(PROGRAM 1)
M³/H - RPM 2
(PROGRAM 2)
M³/H - RPM 3
(PROGRAM 3)
M³/H - RPM 4
(PROGRAM 4)
9 - 24V DC/AC
Section 4

Advertisement

loading