Pentair INTELLICOMM II Installation Manual page 3

Interface adaptor

Advertisement

Available languages

Available languages

3
Disclaimer of liability
There are a multitude of factors that contribute to the life of your pool.
Please be aware that over time, deterioration, discoloration and brittleness of any pool finish can be caused separately by, or in
combination with, age, an imbalance in pool water chemistry, improper installation and other factors.
The same situation holds true for vinyl-lined in-ground swimming pools, because vinyl liners are also affected by the environment
and factors such as pool water chemistry, sunlight and the pool's surroundings. Therefore over time, vinyl can become brittle and
weak. In addition, vinyl-lined pools are affected by the workmanship, composition and installation of the liner and the workmanship
and quality of construction of the supporting walls and pool base. These are all factors which can contribute to liner failure. The
manufacturer disclaims any liability for repairs or replacement to any of these structures or components of the customer's pool.
The pool owner must assume all responsibility for the condition and maintenance of the pool's surface, water and deck.
Before the IntelliComm II is installed, please take a moment to record the serial number. You will be asked for this number when you
contact our Technical Support Department.
• IntelliComm II Interface Adapter
• Two mounting screws
• Mounting tape
• One Terminal Connector (RS-485 and IntelliComm II power connection)
• Four AUX cables (22 AWG)
• Installation and User's Guide (this manual)
• Communication cable for IntelliFlo (P/N 350122)
The IntelliComm II interface adaptor provides automatic control of IntelliFlo VF and IntelliFlo VSD. The IntelliComm II interface
adaptor is compatible with ControlPro Filtration Manager and others. The IntelliComm II Interface adaptor provides:
Four input (9-24V DC/AC) program terminals (m³/h - RPM 1, 2, 3, and 4) for connection to any available auxiliary relay, valve
actuator or controlled output circuit on the automation control system circuit board. Typically, m³/h (RPM) 1 connects to the output
Filter Pump relay terminal plug. You can also connect to the spa, pool electric heater, solar or 2-speed pump output circuit. Each
of the four inputs can be used to control the IntelliFlo pump's speed or flow. Note: If more than one terminal input is active, the
highest input number (m³/h - RPM 4) will take priority regardless of the pump setting.
A four screw terminal connector for connection to the RS-485 IntelliFlo communication cable and power source (9-24V DC) from
the automation control system circuit board.
Note: The IntelliComm II Interface adaptor will always use ADDRESS 1 to communicate with the IntelliFlo pump.
Selecting Flow Rates (m³/h) for IntelliFlo VF Pump
The IntelliFlo VF pump can be selected to run at a specific m³/h, for each external control input:
IntelliFlo VF: 3.4 to 29.5 m³/h
Selecting Pump Speeds (RPM) for IntelliFlo VSD Pump
The IntelliFlo VSD pump can be selected to run at a specific speed (RPM), for each external control input:
IntelliFlo VSD: 400 - 3450 RPM
SERIAL #__________________________________
IntelliComm® II Interface Adaptor Kit Contents
IntelliComm II Interface Adaptor Overview
Section 1
Section 2