7.2 Dispenser Installation

1. Turn off the power switch.
2. Remove the top cover and middle cover shown in Figure 7-1.
3. Remove gear (27) and gear (31).
4. Plug spring-peeler (83) into the right hole on chassis 2 and lock screw (F) up.
5. Put shaft-peeler (86) and peeler-switch (88) into shaft-peeler (87) and then insert it in
hole on right side.
6. Guide peeler-switch (85) going through shaft-peeler (87).
7. Hook spring-peeler (83) on the circle notch of shaft-peeler (87).
8. Put spring-peeler (84) into the left hole of chassis 2 and lock screw (F) up.
9. Put peeler-switch (89) into shaft-peeler (87).
10. Hook spring-peeler (84) on the circle notch of shaft-peeler (87).
11. Put back gear (27) and gear (31).
12. Mount the cable into chassis 2 and plug the other side into the label on the main board.
13. Close the middle cover.