Changing switch mode (impulse/permanent contact)
Installation
1.
Using the key supplied, unscrew the cover screws and remove the cover
plate.
2.
Remove the two PCB screws on the left and right of the cylinder.
3.
Pull the cylinder and PCB carefully upwards and out.
4.
Use the back of the key-switch case as a template for marking the drill
holes (2). Drill the holes for the fixing screws.
5.
Pull the connector cable through the opening provided.
6.
Fix the casing to or in the wall.
7.
Connect the cables to the terminal block (8) as described.
8.
Replace the PCB in the casing, replace the cover (1) and tighten the cover
screws. Make sure that the sealing ring sits firmly in the housing groove.
Technical data
Voltage supply LED
Max. power consumption per LED
Maximum contact capacity
Dimensions (surface fitting)
Dimensions (flush fitting)
Protection type
Number of contacts
Weight
The manufacturer reserves the right to make technical modifications without
prior notice.
1. The factory setting of the key switch is
permanent contact. To change the switch
mode:
Permanent
2. Remove the upper part of the clamp and
swing it to the side.
3. The key switch is now set to impulse mode.
Impulse
10–15 V DC
2mA
30V DC / 0.5A
85 x 114 x 42mm (WxHxD)
106 x 134 x 42mm (WxHxD)
IP55
3 (switchable)
450g
8