Replacing Electronic Main Board With Power Button - Nescafe Dolce Gusto KRUPS KP 2106 Service Manual

Beverage center
Table of Contents

Advertisement

The power button is
part of the PCB
assembly and cannot
be replaced separatedly.
The electronic
main board is sensi-
ble to electrostatic dis-
charge - use safety meas-
ures.
R E P A I R

Replacing electronic main board with power button

Valve
O
P
Safety
Line
1. Follow partial disassembly (see page 26).
2. Unplug all electrical connections from electronic main board (K):
- NTC connector (J)
- valve connector (O, to microswitch)
- safety connector (P, to reed switch)
- 3 flat receptacles (Q)
The flat receptacles (Q) on the electronic board have a
special connector latching.
Press down lever at first, then pull receptacle.
3. For soldered wire (R) on electronic main board:
Unplug flat receptacle from thermoblock.
4. Release 3 latches (S) of PCB assembly and remove defect electronic main board.
Assembly information
For handling the new electronic main board, the service technician must be earthed
using an earthing strap.
For correct wiring refer also to electrical wiring diagrams - see page 50.
Make sure that the left housing cover is fitting exactly and does not affect the func-
tionality of the power button.
J
K
NTC
Heater
Neutral
Pump
R
Q