8.3.
Checking & Repairing SMPS
P.C.B
• Follow the (Step 1) - (Step 8) of item 8.2.
Step 1 : Remove 4 screws.
Step 2 : Detach 8P FFC cable at the connector (CN5500) on D-
Amp P.C.B.
Step 3 : Detach 11P FFC cable at the connector (CN5802) on
SMPS P.C.B.
Step 4 : Remove SMPS P.C.B. as arrow shown. Be careful
with the guide.
Step 5 : Connect 8P cable at the connector (CN601) on Panel
P.C.B..
Step 6 : Connect 9P cable at the connector (CN602) on Panel
P.C.B..
Step 7 : Connect 8P cable at the connector (CN5500) on D-
Amp P.C.B..
Step 8 : Connect 11P cable at the connector (CN5802) on
SMPS P.C.B..
Step 9 : Check & repair SMPS P.C.B. according to the diagram
shown.