Fabricated Test Equipment; Test Equipment Required For Maintenance - HP 608E Operating And Service Manual

Vhf signal generator
Hide thumbs Also See for 608E:
Table of Contents

Advertisement

Model 608E!F
Table 5-1. Test Equipment Required for Maintenance (Cont.)
Section V
Instrument
Critical Specifications
Recommended Model
DC Ammeter
Range: 15 to 30 mA
HP 428B
Accuracy: .±5%
SWR Meter
Sensitivity: at least
JJ.
v full scale
HP 415E
Attenuator Range: 40 dB
Attenuator Accuracy: :to. 1 dB
Double Balanced Mixer
Frequency Range: 10 to 480 MHz
HP 10514A
Frequency Comb
Frequency Range: 10 to 480 MHz
HP 8406A
Generator
Comb Frequency:
1 MHz
Filter
Cutoff Frequency:
100 kHz
Frequency Meter!
Discriminator Output: 100 kHz!V
HP 5210AIlO531A
Filter Kit
Disc. Out Accuracy: Better than 1%
Internal Filter: 10 kHz, low pass
Oscilloscope
Bandwidth: o to 20 MHz
HP 140 with 1406A plug-in unit
Vert Sensitivity: 50 JJ.V,tm
LAB Dual Range.
Output: o to 20
Vd,
HP 6204B
DC Power Supply
Electronic Counter
Resolution: 5 digits
HP 5246L with 5252A
Function: Frequency to
>
350 MHz
plug-in unit
Input Impedance: 50 ohms
Synchronizer
Compatible
with
the 608 F
HP 8708A
LOOP ANTENNA
6 IN. - - - - - - - - - - -
INSULATED 16-GUAGE
COPPER WIRE
100 OHM! 10%
7'
112
WATT
FEMALE BNC
CONNECTOR
IOO-OHM LOAD
UG·I094/U
FEMALE
BNC
CONNECTOR
Figure 5-1.
Fabricated Test Equipment
5-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

608f

Table of Contents