Maxell MXFC-1000 Instruction Manual

Rechargeable moisturization support device

Advertisement

Quick Links

Rechargeable Moisturization support device
MXFC-1000
Instruction Manual
Thank you for buying Maxell product.
Please read this manual to use correct in advance.
Please keep this manual carefully.
1.5hr Rechargeable
For household use only

Table of contents

1
2
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
PA1215 - 00
2
5
5
6
7
10
12
22
22
23
25
26
27

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MXFC-1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Maxell MXFC-1000

  • Page 1: Table Of Contents

    PA1215 - 00 For household use only Rechargeable Moisturization support device MXFC-1000 Instruction Manual Thank you for buying Maxell product. Please read this manual to use correct in advance. Please keep this manual carefully. 1.5hr Rechargeable Table of contents Safety Precautions...
  • Page 2: Safety Precautions

      Safety Precautions Precautions described here are intended for safe and correct use of this product and are ● to prevent injury and damage to you and others before they occur. Precautions are classified as follows. ● Make sure to observe the precautions because they are all important in relation to safety. Indicates an imminently dangerous situation in which improper handling may result in death or serious injury to a user.
  • Page 3 Do not use this product on the following regions. (Cause of accident or trouble) - Regions where orthopedic treatment was given - Eyeballs and upper eyelids - Wound sites - Facial melanoderma - Mucosal regions, such as inside the mouth - Regions irritated due to pimples or skin rash - Lips - Regions which suffer from sensation of pain or perception disorder...
  • Page 4 For the purposes of recharging the battery, only use the detachable supply unit provided with this appliance Model No. : KH-55M (Possibility of electric shock or ignition) >$?(*)<1(* Do not insert or remove the power plug in/from the outlet with wet hands. (Cause of failure or short circuit) C)(*D.07*D(0* 7$34)*&1+7.9.0(4...
  • Page 5: Feature Of The Product

      Feature of the product ●Spot sensor Device finds spot, and notify by vibrator ●Warm function Comfortable warm cleansing and moisturization support ●Cool function Cool down of the skin and tighten of pores ●Memory function Electric level is memorized after power off ●Notification timer function Notify by "Pi,Pi"...
  • Page 6: Device Details

      Device details Thermal head LEVEL indicator (Titanium) 1(Low)(Green) Vibrate while using except 2(Mid)(Green) "COOL" mode 3(High)(Red) After press Power button, Spot sensor "1""2" or 3 lamp lights. When Spot sensor finds a spot or others, notify by vibration. LEVEL switching button Mode indicator Electric level changes by each press.
  • Page 7: Preparation Before Use

    Power adaptor Model No. : KH-55M Power plug Insert deeply to the socket Plug to connect Attachment the device Cord Ring(2pcs) Ring is for cotton fix to the device. Protective cap   Preparation before use Charging method At first time to use after you bought this product, you need to charge the battery. Electrical power should be used 100-240V by alternative current, then please use attached Power adaptor.
  • Page 8 ❷ After completed charging time(approximately 1.5hr), please unplug Power adaptor from the socket. ・ In charging process, device and power adaptor heat up a few, but it is not abnormal. ・ This device is for rechargeable exclusive. Can not use while power cord connect to the device.
  • Page 9 ❶ Mode and skin lotion Cotton and skin lotion Mode CLEANSING(HOT) Please use new cotton which is soaked with your regular skin lotion. (Remove fine dirt in pores) When using cotton MOISTURIZE(HOT) Use new cotton soaked with your regular skin lotion. (Performs moisturizing care by allowing moisturizing ingredients to When not using cotton...
  • Page 10: Example For Use

    ❺ Please note the following to avoid a damage your skin. (1) Basic mode usage frequency of this device is 8 min. at once per day at a person. ・ Please do not use the device for over 3 min. per day in each step. (Step 1, 2 and 3). ・...
  • Page 11 Quick Treatment (Required time: approximate 3 min.) ●Step 2 "MOISTURIZE(HOT)" When you do not have much time in the morning or when you need to go out suddenly, you can just use "MOISTURIZE(HOT)." It only takes approximate three min. to moisturize your skin thoroughly.
  • Page 12: How To Use

    Weekly Full Course (Required time: approximate 11 min.) ●Step 1 "CLEANSING(HOT)" ●Step 2 "MOISTURIZE(HOT)" ●Step 3 "MASK(HOT)" (use of sheet mask) ●Step 4 "COOL" Care for your skin once or twice a week by using all modes. Fine vibrations in "MASK(HOT) (use of sheet mask)" mode and gentle switching of the electrode will condition the skin.
  • Page 13 ❸ Select electric level by LEVEL switching button. Switch the "strength" with the level switch button according to the condition of your skin. Every time the level indicator button is pressed, the "1","2" and "3" of the electrical potential will be switched. There will be no change in vibration strength. The memory function memorizes the "strength"...
  • Page 14 ❻ Automatically shut down after 3min.(Auto-off function) Notify by End sound(Pi Pi) ❼ Remove ring and cotton Wipe off the surface of the Thermal head with a tissue. Do not use the cotton again once it is used. It might cause problems with your skin. Step 2 "MOISTURIZE(HOT)"...
  • Page 15 ❻ Apply cotton to the skin and move the device slowly. Mode indicator lamp will turn on and the device will start to vibrate. The time for use is within approximate 3 min.. CAUTION Unless you apply the cotton to your skin while touching the back plate, the device will not vibrate.
  • Page 16 When not using cotton Also you can use the device without cotton in "MOISTURIZE(HOT)" ❶ Apply a gel-like moisturizing product or Skin lotion      thick skin lotion that you would normally use onto Thermal head and smoothen it over the entire head with your fingers. Thermal head MODE indicator ❷...
  • Page 17 ❺ Please touch Thermal head to your skin, and move slowly. Mode indicator lamp will turn on and the device will start to vibrate. The time for use is within approximate 3 min. Spot sensor The device finds a spot on your skin, and notify by strength of vibration. ・The device notify to you by changing Spot Light...
  • Page 18 ❻ After using 3 min., the device will turn off automatically. (Auto-off function) Notify by End sound(Pi Pi) ❼ Wipe off the surface of the Thermal head with a tissue. STEP 3 MASK (Regarding recommendation usage, in case of milky lotion, once per day, in case of Sheet Mask, once or twice per week is recommendation frequency) This device provides good effective of milky lotion and sheet mask by fine vibration and slow electrode switching.
  • Page 19 Notification timer function Skin care time is indicated by the buzzer beeping about every 45 sec. as a guide. [Example of skin care sequence] Divide the area from your face to décolletage into four zones as shown in the illustration. By moving the Thermal head in the order of ①②both cheeks->③T-zone④dé...
  • Page 20 ❶ Press Power button. MODE indicator LEVEL indicator lamp The level indicator lamp will turn off, and lamp "COOL" on the mode indicator lamp starts flashing. If a lamp in another mode is flashing, please press the mode switching button to select to "COOL"...
  • Page 21 Skin detective function This device is a product which operates through the human body. Applying the skin to the earthing plate and the head will make an electrical circuit start to operate. Unless you touch the back plate and apply the head to the skin, it will not start to operate. Memory function This device has a memory function to memorize of the electrical strength levels of "1"...
  • Page 22: Care Of The Device

        Care of the device Wipe off any remaining cosmetic on the Thermal head, spot sensor, cooling head, main body and ring with a tissue paper, etc. Do not clean the main body with water. Do not soak in water, and do not pour water on the main body. (Cause of failure) Do not soak the head in boiling water or dry it with hot air.
  • Page 23: Faqs

    FAQs Please confirm the following if device is not correct movement. If it is not returned to correct condition, please contact the distributor. Condition Check point How to repair It cannot be Please unplug Power adaptor from Check Power adaptor is Power turn on.
  • Page 24 Condition Check point How to repair Vibration strength Check some stain attach to Please wipe it out by tissue or is not changed Shimi-Navi sensor, or not. cotton bar. under Shimi-Navi detection. Size of cotton is different Please use other cotton. It cannot attach the ring.
  • Page 25: Trouble Shooting

    Trouble Shooting Q1. Tingling sensation is felt on the skin. ● Check the intensity level. If it is set on "3" level, please press the level switching button to change to "1" level. ● If skin lotion in the cotton pad wears off, replenish it again. ※...
  • Page 26: Specification

    Q8. Can I use milky lotion or gel? If you use cotton, you can not use cosmetics other than skin lotion. ● Please use skin lotion which has keratin removal effect or others. Milk-based lotion or gel can be used when using " MOISTURIZE(HOT)" mode without ●...
  • Page 27: Disposal Of Product

    1 3 Disposal of product ・With the removed batteries, do not charge and avoid the following.   (Cause of heat generation, ignition, or explosion) Do not throw batteries into a fire, or overheat them. Do not puncture with a nail, give an impact, disassemble, or modify them. Do not bring ( +...
  • Page 28 Screw cap ❷ Remove the three screw concealing pieces and the three screws on the back of the body. Screw (-) Driver ❸ Insert a flat blade screwdriver etc., into the gap between the body cases (front) and (rear), and remove the body case (rear). Main body(Rear) Main body(Front) ❹...
  • Page 29 CAUTION Make sure to pull out the device plug from the main body after charging. Do not store to keep wrapping around by code to the body of device and also avoid to keep connecting device plug. Cord Do not wrap around the cord to the body Device plug.
  • Page 30 NOTICE Attention for Use Make sure to hold the main body of the product with your hand ● touching back plate and apply the of the product heating dimple head to your skin. Otherwise, the product will not be operated. Back plate About Skin Detective Function This product which is operated through the human body.

Table of Contents