Factory setting
0.5
Important! Only selectable when "pulse key" has been pressed.
Tdown Downslope time
Unit
S
Setting range
0—10
Factory setting
0
Ic
Crater arc current (only with 4T)
Unit
S
Setting range
5—100% of main current Iw (DC);10—100% of main current Iw (AC)
Factory setting
5
Tpo
Gas post-flow time
Unit
S
Setting range
1—10.0
Factory setting
3
AC frequency (only with TIG-AC)
Unit
Setting range
50—200 ( 70A≤Iw<100A)
50—150 (100A≤Iw<140A)
50—120 (140A≤Iw<170A)
50—100 (170A≤Iw)
Balance (only with TIG-AC)
Balance adjustment is mainly used to set the adjustment of eliminating metal-oxide (such as Aluminium,
Magnesium and its alloy) while AC output.
Unit
%
Setting range
15—50
Factory setting
15
(8) Rod electrode(MMA) welding key
Hz
50—250 (Iw<70A)
Parameter
Arc force
Hot start
Arc length
OPERATION
Setting range
0-10
0-10
0-10