mMINT-Modbus Translator Module-
installation and use
Effective May 2010
Contents
Description
List of figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
List of tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Section 1: General description . . . . . . . . . . . . . . . 3
Section 2: Features . . . . . . . . . . . . . . . . . . . . . . . . 3
Section 3: Installation . . . . . . . . . . . . . . . . . . . . . . 3
Module mounting . . . . . . . . . . . . . . . . . . . . . . . . 3
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Power connections . . . . . . . . . . . . . . . . . . . . . . 4
INCOM connections . . . . . . . . . . . . . . . . . . . . . 4
Modbus connections . . . . . . . . . . . . . . . . . . . . . 4
INCOM network Rx LED (green) . . . . . . . . . . . . 5
INCOM network Tx LED (green) . . . . . . . . . . . . 5
Status LED (green) . . . . . . . . . . . . . . . . . . . . . . . 5
INCOM 100 load resistance
(DIP switch SW1) . . . . . . . . . . . . . . . . . . . . . . . . 5
Modbus RS-485 baud rate
(DIP switch SW2) . . . . . . . . . . . . . . . . . . . . . . . . 5
mMINT diagnostics address (SW2) . . . . . . . . . . 5
Modbus 121 load resistance
(DIP switch SW3) . . . . . . . . . . . . . . . . . . . . . . . . 5
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Function codes . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Configuring the data registers . . . . . . . . . . . . . . 5
Register access configurations . . . . . . . . . . . . . 6
Control commands . . . . . . . . . . . . . . . . . . . . . . . 6
Data format for energy values . . . . . . . . . . . . . . 7
Exception codes . . . . . . . . . . . . . . . . . . . . . . . . . 7
Section 7: Troubleshooting . . . . . . . . . . . . . . . . . . 7
Appendix A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2C14994H02
Page

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the mMINT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton mMINT

  • Page 1: Table Of Contents

    (DIP switch SW2) . . . . . . . . . . . . . . . . . . . . . . . . 5 mMINT diagnostics address (SW2) . . . . . . . . . . 5 Modbus 121 load resistance (DIP switch SW3) .
  • Page 2 Page Figure 1 . mMINT in a Communications Network . . . . . . . . . . . . . . 3 Table 1 . Pin J1 Voltage Connector . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 2 .
  • Page 3: Section 1: General Description

    IZM . . .P . . . (Digitrip 1150) are equipped with an INCOM interface . The or maintenance . mMINT is master on the IMOM side and slave on the Modbus side . m WARNING Modbus RTU Network DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENERGIZED.
  • Page 4: Section 4: Mmint Module Connections

    (89 .9) Section 5: Switches and indicator LEDS Figure 2. Connections Refer to Figure 3 to locate the Status LED for the mMINT module . INCOM connections Figure 4 shows the location of the configuration switches . INCOM connector: The three-pole connector is for the INCOM network .
  • Page 5: Modbus Rs-485 Network Rx Led (Green)

    41201/420737 (04B0 /5100 The mMINT can be assigned address 247 and 248 . For the mMINT The total number of data block of registers is limited to 100 . to respond to a diagnostic query related to address 247 or 248 on otee: An object can occupy one, two, or four registers .
  • Page 6: Register Access Configurations

    The four-register format indicates the energy values in watthours . otee: mMINT SW2-1 must be properly set . See Section 5 and Table 5 . These are register 3 through register 0 . Register 3 is of the highest value and register 0 is of the lowest value .
  • Page 7: Supported Diagnostic Sub-Functions

    INCOM device(s) mMINT or INCOM addr It is possible to obtain diagnostics from the mMINT or an attached INCOM product using function code 08 . See Table 6 . A single register is used for each UART counter within the mMINT . Each INCOM device and the mMINT contain a unique slave counter .
  • Page 8 Appendix A otese: ModbusT is a registered trademark of Schneider Electric . mMINT modules use DIN rail mounting . Supply voltage is 120 Vac ±20% or 24–125 Vdc . Connectors are plug-in types from Phoenix Contact . Terminal Types (supplied with module) are three-pole, four-pole, and five-pole manufactured by Phoenix Contact .
  • Page 9: Table 8. Modbus Register Map (In Register Number Order)

    Translator Module— 05/10 AWB1230-1622 installation and use Effective May 2010 Table 8. Modbus Register Map (in Register Number Order) Objects (Complete List) Register Number Modbus Register Address INCOM Products (Partial List) Fixed Point IEEE Float Fixed Point FP Scale IZM...U...
  • Page 10: Table 9 . Modbus Register Map (In Functional Order)

    05/10 AWB1230-1622 mMINT—Modbus Translator Module— installation and use Effective May 2010 Table 9. Modbus Register Map (in Functional Order) Objects (Complete List) Register Number Modbus Register Address INCOM Products (Partial List) FP Scale IZM...U... IZM...P... Name Numeric Units IEEE Float...
  • Page 11: Table 10. Primary Status Code Definitions

    Reverse sequence Emergency override Overfrequency Phase current loss Current unbalance Phase voltage loss Voltage unbalance Alarm active Table 14. mMINT Configuration Registers Apparent power factor Bad frame Register Modbus Address No. of Power demand Phase currents near pickup Register Definition...
  • Page 12 05/10 AWB1230-1622 mMINT—Modbus Translator Module— installation and use Effective May 2010 Eaton Industries GmbH Electrical Sector ©2010 by Eaton Industries GmbH Änderungen vorbehalten Subject to alterations 05/10 AWB1230-1622 / Z8817 Moon/Doku/Heng Printed in USA (05/10)
  • Page 13 (Kippschalter SW1) . . . . . . . . . . . . . . . . . . . . . . . 5 Modbus RS485 Baudrate(Kippschalter SW2) . . 5 mMINT Diagnose-Adresse (SW2) . . . . . . . . . . . 5 Modbus 121 Ω Abschlusswiderstand (Kippschalter SW3) .
  • Page 14: Beschreibung Seite

    Tabelle 14 . mMINT Konfigurationsregister . . . . . . . . . . . . . . . . . 11...
  • Page 15: Abschnitt 1: Generelle Beschreibung

    Lieferung, Installation, Funktionsprüfung, sicheren Betrieb oder die 520MC) und IZM . . .P . . . (Digitrip 1150+) haben eine INCOM- Wartung ab . Schnittstelle . Das mMINT ist Master auf der INCOM-Seite und Slave auf der Modbus-Seite . m Warnung Führen Sie keine inStallation oder Wartung durch,...
  • Page 16: Abschnitt 4: Mmint Modul-Anschlüsse

    (89 .9) Abschnitt 5: Schalter und LED-Anzeigen Abb. 2. Anschlüsse Siehe Abb. 3, für die Status-LED des mMINT Moduls . Abb. 4 zeigt die Positionen der Konfigurationsschalter . INCOM Anschlüsse INCOM Anschluss — Der 3-polige Anschluss ist für das INCOM- SW2 SW3 Netzwerk .
  • Page 17: Modbus Rs485 Netzwerk Rx Led [Grün]

    INCOM Objekte belegen zwei (2) Register, abgesehen von Siehe Abschnitt 6 und Tabelle 6 . bestimmten Energieobjekten . Diese Energieobjekte belegen vier (4) Register . Das mMINT unterstützt maximal 122 Register . INCOM 100 Ω Abschlusswiderstand (Kippschalter SW1) In der Standardkonfiguration sind INCOM -Adressen Modbus- Dieser Schalter sollte in „ON”...
  • Page 18: Konfiguration Des Registerzugriffs

    Diagnoseadresse 247 oder 248 durchgeführt . höchstwertigste und Register 0 ist das niederwertigste Register . inweiss: mMINT SW2-1 muss in der richtigen Position ist . Siehe Abschnitt 5 und Tabelle 5 . Das High Byte von Register 3 enthält einen Faktor . Das Low Byte von Register 3 enthält einen Mantisse-Multiplikatorwert .
  • Page 19: Unterstützte Diagnose-Sub-Funktionen

    Produkt per Funktionscode 08 eine Diagnose zu erhalten . Siehe Tabelle 6 . Für jeden UART (universelle asynchrone Parallel-Seriell Schnittstelle)-Zähler innerhalb des mMINT wird ein einzelnes Register verwendet . Jedes INCOM Gerät und das mMINT verfügen Abschnitt 7: Fehlersuche und-behebung über einen eigenen Slave-Zähler .
  • Page 20: Anhang A

    Anhang A inweiss: Modbus® ist eine registriertes Markenzeichen von Schneider Electric . mMINT Module verwenden DIN Schienenmontage . Versorgungsspannung 120V AC ±20% oder 24 – 125V DC . Verbindungsstecker vom Typ plug-in von Phoenix Contact . Terminaltypen (mitgeliefert) sind 3-polig, 4-polig und 5-polig von Phoenix Contact .
  • Page 21 Installation und Benutzung des 05/10 AWB1230-1622 mMINT Modbus Translator Moduls Gültig ab Mai 2010 Tabelle 8. Modbus Registerverzeichnis (in Reihenfolge der Registernummern) objekte — (komplette liste) registernummer modbus register-adresse incom produkte — (teilliste) gleitkomma gleitkomma izm...u... izm...p... (Fixed point ieee Float...
  • Page 22 05/10 AWB1230-1622 Installation und Benutzung des mMINT Modbus Translator Moduls Gültig ab Mai 2010 Tabelle 9. Modbus Registerverzeichnis (in funktionaler Reihenfolge) objekte — (komplette liste) registernummer modbus register-adresse incom produkte — (teilliste) gleitkomma izm...u... izm...p... gleitkomma ieee Float (Fixed point...
  • Page 23: Tabelle 10. Primäre Statuscode-Definitionen

    VA-Anforderung Augenblicklicher Phasenüberstrom register adresse # von VAR-Anforderung Sollwertfehler registerdefinition high high regs Strom anfordern Über Temperatur mMINT (247 oder 248 adressiert) Totale Zubehörbus Ungültige 42001 425345 07D0 6300 Oberschwingungsverzerrung Objektzugriffskonfiguration Betriebssumme Lange Verzögerung Neutral-Überstrom Gleitkommadaten- 42002 425346...
  • Page 24 05/10 AWB1230-1622 Installation und Benutzung des mMINT Modbus Translator Moduls Gültig ab Mai 2010 Eaton Industries GmbH Electrical Sector ©2010 by Eaton Industries GmbH Änderungen vorbehalten Subject to alterations 05/10 AWB1230-1622 / Z8817 Moon/Doku/Heng Printed in USA (05/10)