Clearance To Combustibles; Hearth; Electrical Specifications; Electrical Connections - Vermont Castings ACSB ACSM Installation Instructions And Homeowner's Manual

Freestanding electric stove
Table of Contents

Advertisement

Clearance to Combustibles

Back .............................................................. 0" (0 mm)
Sides ............................................................. 0" (0 mm)
Floor .............................................................. 0" (0 mm)
Top ........................................................... 12" (305 mm)
A hearth is not mandatory but it is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which does not obstruct heater openings.
Electrical Specifications
Voltage .......................................120VAC/60Hz
Total Amps .................................12.20 Amps
Total Watts .................................1460 Watts
Heater Ratings ...........................1300 Watts
Installation of Logs
1. Turn off power to the unit.
2. Follow the directions for removing the firebox. Refer
to Page 6, Steps 1 through 7.
Fig. 2 Addison logset.
30002351

Hearth

LG369
Addison logs
11/04
A 15 AMP, 120 Volt, 60 Hz circuit with a properly
grounded outlet is required. Preferably, the stove will be
on a dedicated circuit as other appliances on the same
circuit may cause the circuit breaker to trip or the fuse
to blow when the heater is in operation.
The unit comes standard with a 6' (1828 mm) long
three wire cord, exiting from the rear of the stove. Plan
the installation to avoid the use of an extension cord. If
an extension cord must be used, it must be a minumum
14AWG, three wire with grounding type plug connec-
tor and rated not less than 1875 Watts. The extension
cord shall not be more than 20 feet in length.
WARNING: Electrical outlet wiring must
comply with local building codes and
other applicable regulations to reduce the
risk of fire, electrical shock and injury to
persons.
WARNING: Do not use this stove if any
part of it has been under water. Immedi-
ately call a qualified service technician to
inspect the stove and replace any part of
the electrical system.
LG369
Addison Electric Stove
Electrical Connection
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Addison acsbAddison acsm