The Damper Stop provided keeps your damper
from accidentally closing during operation of your
set. This Damper Stop must be installed onto
your Damper at all times. NOTE: The damper
clamp is designed to hold the damper plate
open 3 inches. However, the damper must be
fully open when the log set is in operation.
Install the Damper Stop onto the edge of the
damper plate. Attach by securing the bolt pro-
vided to the damper plate with an adjustable
wrench. (Fig. 3)
If the Damper Stop does not fit, drill a 1/4" hole
into the damper plate and install an
anchor bolt with nut, at a 90 degree angle, so that
the damper plate will remain fully open.
The proper finished installation of the Damper
Stop is shown in Figure 4. If the bolt fails to block
the damper in an open position, the damper
should be removed from the chimney.
To check your vent for proper drafting: Light a
tightly rolled newspaper on one end and place it
at the inside front edge of the fireplace. Observe
the smoke and be sure the vent is properly
drawing it up the chimney. If the smoke is drawn
back into the room, extinguish the flame and
1. Place the burner pan in the fireplace. The
burner pan should be located several inches
from the back wall, centered from right to left.
NOTE: This is for burner connection purposes
only. Exact burner placement will be covered
on page 8, after all connections have been
made.
2. Attach the Gas Supply Fitting onto your
fireplace's gas supply pipe, as shown in Figure
5.
3. Attach one end of the Flexible Gas Connector
to the brass Burner Inlet Fitting which has
been factory installed into the burner.
4. Attach the other end of the Gas Connector to
the flared side of the Gas Supply Fitting.
Remember to use pipe thread sealant or teflon
tape only on the straight pipe threads. Do not
use on any flared ends.
6
Damper Stop Installation:
For Use With All Other Fireplaces
Connection to Gas Supply
Figure 3
Damper
Clamp
Damper
Figure 4
Figure 5a
Damper Plate
Damper Stop
DP104
DP103
CFM149
20003889