Transport; Disposal And Recycling; Troubleshooting - Scheppach DH6000 Translation From The Original Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H 07 RN".
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate
MAINS CONNECTION
• The compressor is equipped with a mains cable
with shock-proof plug. This can be connected to
any 230V ~ 50 Hz shock-proof socket which is pro-
tected by a 16 A fuse.
• Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
• Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor
start-up.
• At low temperatures below +5°C, sluggishness
ticipate in the proper disposal of the device. The used electrical device can be given over to a collection point where the
disposal will be carried out according to the national recycling management and waste law. To receive information regard-
ing public collection points, please contact the responsible local authority.

13. Troubleshooting

Fault
Possible cause
E1
Coil Sensor-Error
E2
Moisture Sensor-Error
E3
Temperature Sensor-Error
E4
Hot and Cold System-Error
E5
Room Temperature too high
ERROR
Dehumidifier does not work.
Bad Dehumidification Perfor-
mance
High Noise Level
Water flows out of the device
Remedy
Exchange the coil sensor.
Exchange the moisture sensor.
Exchange the temperature sensor.
Have the dehumidifier checked /repaired by a specialist.
Lower the room temperature and
dehumidifier will restart automatically.
ERROR
Device has no power.
Mains plug is not plugged in prop-
erly.
Display shows error code E4.
Air in- or outlet is covered.
Room is not closed.
Low moisture and temperature.
Device was not put on even ground.
Air in- or outlet is covered.
Leakage of the water collecting con-
tainer.
may make starting difficult or impossible.

12. Transport

Always transport the air dehumidifier in upright (verti-
cal) position to prevent compressor damages.
If you have transported the air dehumidifier in another
than upright position (horizontal or tilted), allow the air
dehumidifier to stand in upright position for at least
one hour before starting it up.

13. Disposal and recycling

Please dispose the appliance, its ac-
cessories and packaging environ-
mentally friendly and do not dispose
them in household garbage (2012/19/
EU). Within the EU, this symbol indi-
cates that this product may not be dis-
posed of with household waste. This article contains
valuable recyclable materials and should be fed to a
recycling system to protect the environment and hu-
man health that could be damaged from uncontrolled
waste disposal. Please dispose of the product using
appropriate collection systems or send the product
for disposal to the place where you bought it. From
there the product will then be delivered to recycling.
Recycling-alternative to returning the product:
The owner of the electrical device is, alternatively in-
stead of shipping the device back, obligated to par-
SOLUTION
Turn on the power supply.
Connect the mains plug properly.
Empty the water collection container.
Uncover Air in- and outlet.
Close all doors and windows.
The lower the room temperature the
worse the dehumidification perfor-
mance.
Position the device on even ground.
Uncover Air in- and outlet..
Check the water collecting container.
Replace the water collecting con-
tainer.
21 І 36
21 І 36

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5906501901

Table of Contents