Toro Reelmaster 7000-D Service Manual page 281

Hide thumbs Also See for Reelmaster 7000-D:
Table of Contents

Advertisement

9. Disconnect voltage and test leads from the relay ter-
minals.
10.If testing determines that the relay is not functioning
correctly, replace the relay.
11. If the relay tests correctly and a circuit problem still
exists:
A. Check wire harness (see Electrical Schematic
and Wire Harness Drawings in Chapter 10 − Foldout
Drawings in this manual).
B. Use the InfoCenter Display to check specific TEC
output operation (see InfoCenter Display in this
chapter).
12.Secure relay to mounting bracket and connect wire
harness connector to relay.
13.Secure all removed components to machine.
Reelmaster 7000−D
14.Connect positive (+) cable to battery and then con-
nect negative (−) cable to battery (see Battery Service
in this chapter).
1. Coil terminal
2. Common terminal
Page 6 − 55
3
3
4
1
1
Figure 60
3. Normally closed term.
4. Normally open term.
Electrical System