HealthWay SuperV Series Manual

HealthWay SuperV Series Manual

Dfs filtration system

Advertisement

The Super V Whole-House Air Cleaner
with Patented DFS Technology
SUPER V-BANK FILTER
HIGH-ENERGY GRID
Model3400/5100
DFS Filtration System

Advertisement

Table of Contents
loading

Summary of Contents for HealthWay SuperV Series

  • Page 1 The Super V Whole-House Air Cleaner with Patented DFS Technology SUPER V-BANK FILTER HIGH-ENERGY GRID Model3400/5100 DFS Filtration System...
  • Page 3: Table Of Contents

    Appendix A - Installation Schematics.....19 Appendix A1 - 120V with EAC ........20 Appendix A2 - 120V without EAC ......21 Appendix A3 - 208-480V with EAC ......22 Appendix A4 - 208-480V with EAC ......23 Healthway © 06/2019 All rights reserved.
  • Page 4: Exploded View And Major Features

    HEPA Filtration – Lower Maintenance Cost SUPERV 3400 EXPLODED VIEW High Energy Grid High Energy Wire Main Filter Filter Access Door Snap Latch Main Housing DFS Light Power Switch High Energy Contact Pad Exploded View 1: 3400 Whole Unit Healthway © 06/2019 All rights reserved.
  • Page 5: Superv 5100 Exploded View

    ** Fuse and fuse holder locates inside the filter access door compartment and is only accessible by unscrewing part 16 - mounting screw, to open up the metal board. *** Refer to Appendix A for slide switch setting. Healthway © 06/2019 All rights reserved.
  • Page 6: System Overview

    Up to 100% 0.030 Removing PM 2.5 Up to 99.99% 0.020 Removing PM 0.5 Up to 99.87% Removing PM 0.3 Up to 99.61% Removing PM 0.007 Up to 99% Performance data subject to change without notice. Healthway © 06/2019 All rights reserved.
  • Page 7: Unit Description

    ** Replace Main Filter more often if pollution level is high ***Clean the High Energy Grid once a year or as needed Components Description Filter Access Door Where the control panel , air flow monitor and electrical components located Healthway © 06/2019 All rights reserved.
  • Page 8: Receiving And Unpacking

    Carefully unbox the carton, remove the foam pieces on top and slowly pull out the unit covered with a plastic protection bag. Remove the plastic bag. Inspect physical damage on the unit surface as well as the power cord. Contact Healthway’s Customer Service Department if damage is found.
  • Page 9: Power Requirement

    Connection). Fig. 1-2 Up Flow Furnace Fig. 1-3 Down Flow Furnace Fig. 1-4 Up Flow Furnace Vertical Cleaner Horizontal Cleaner Horizontal Cleaner (reverse) Supply Duct Inlet Duct Furnace Fig. 1-5 Horizontal Furnace, Vertical Cleaner Healthway © 06/2019 All rights reserved.
  • Page 10: Superv 3400 Furnace Installation

    Turn the quarter-turn clockwise to lock the filter (Fig. 2-4) Seat the Filter access door on the bottom snap latch, pull up the top snap latch and push close the door towards the housing. (Fig. 2-8) Fig. 2-7 Fig. 2-8 Healthway © 06/2019 All rights reserved.
  • Page 11: Superv 5100 Furnace Installation

    (Fig. 2-12) Seat the Filter access door on the bottom snap latch, hold up the top snap latch and push close the door towards the housing. (Fig. 2-16) Fig. 2-15 Fig. 2-16 Healthway © 06/2019 All rights reserved.
  • Page 12: System Operation

    Maintenance When replacing filters use only HealthWay certified filters. HealthWay filters are designed for high voltage operation. Use of non-HealthWay filters can be hazardous to personnel and equipment voiding the warranty.
  • Page 13: Superv 5100 Filter Replacement

    Place high energy grid on a flat, clean and dry surface with high energy wires facing up (Fig. 3-19) Connect both the contact red wires from the high energy grid to the new filter by securely screwing in the connector (Fig. 3-18) Fig. 3-15 Fig. 3-16 Healthway © 06/2019 All rights reserved.
  • Page 14: Cleaning The Unit

    High Energy Grid assembly for cleaning as previously described. It is recommended that the manufacturer be contacted for detailed instructions should this step appear necessary. Reinstall the High Energy Grid, V-Bank Main Filter and filter access door as previously instructed. Healthway © 06/2019 All rights reserved.
  • Page 15: Phone No: 315-298-2904

    Maintenance PARTS LIST HealthWay recommends that the following spare parts be available on-site at all times. Order all parts by contacting: Phone No: 315-298-2904 1-800-843-3860 Fax No: 315-298-6992 Email: info@healthway.com Super V 3400 Part Description Part Number Main Filter Super V main filter assembly...
  • Page 16: Dfs Troubleshooting Guide

    If the Blue LED lights and stays lit, the problem has been solved. Symptom #2: Blue LED Never turns on. Probable Cause #1: Filter Access Door not completely shut. Solution: Same as Symptom #1, Probable Cause #2. Healthway © 06/2019 All rights reserved.
  • Page 17 Step 7: Reinstall Filter Access Door, Plug in Super V and return power to the furnace. Repeat testing steps 1 – 3. If these steps do not resolve any issues with the Healthway Super V System, please contact an HVAC professional for further troubleshooting and repair as any further action requires repair or replacement of non-user serviceable parts.
  • Page 18: Limited Warranty

    Super V Air Cleaner which is found to be defective within such five (5) year period and which is returned not later than thirty (30) days after said five (5) year period by you or your original supplier to Healthway, Pulaski, NY 13142, together with the model number and installation date of the Super V.
  • Page 19: Appendix A - Installation Schematics

    1. Transformer: UL listed, by Functional Device, PN: TR40VA013, VA Rating; 40, 50/60Hz, Primary voltage: COM 208/240/277/480, Secondary voltage: 120Vac. 2. Relay: UL listed, by Functional Device, PN: RIBXGHF, 0.5-150 amps, 120V, Max Sense Voltage: 600Vac. Healthway © 06/2019 All rights reserved.
  • Page 20: Appendix A1 - 120V With Eac

    Appendix A1 - 120V with EAC Healthway © 06/2019 All rights reserved.
  • Page 21: Appendix A2 - 120V Without Eac

    Appendix A2 - 120V without EAC Healthway © 06/2019 All rights reserved.
  • Page 22: Appendix A3 - 208-480V With Eac

    Appendix A3 - 208-480V with EAC Healthway © 06/2019 All rights reserved.
  • Page 23: Appendix A4 - 208-480V With Eac

    Appendix A4 - 208-480V without EAC Healthway © 06/2019 All rights reserved.
  • Page 24 ® 3420 Maple Ave. Pulaski, New York 13142 USA Toll Free: 1-800-843-3860 Int’l: 1-315-298-2904 healthway.com...