Installation Of Indoor; Selection Of The Best Location - LG AMNW09GL1A2 Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION OF INDOOR

Selection of the best location

Install the air conditioner in the location that
satisfies the following conditions.
- The place shall easily bear a load exceeding
four times the indoor unit's weight.
- The place shall be able to inspect the unit as
the figure.
- The place where the unit shall be leveled.
- The place shall easily connect with the
outdoor unit.
- The place where the unit is not affected by
an electrical noise.
- The place where air circulation in the room
will be good.
- There should not be any heat source or
steam near the unit.
Top view
Inspection hole
Unit: mm(inch)
(600 x 600)
600
Side view
Unit: mm(inch)
* Suitable dimension "H" is necessary to get a
slope to drain as shown in the figure.
Confirm the positional relationship between
the unit and suspension bolts.
- Installation the ceiling opening to clean the
filter or service under the product.
Control box
Air outlet
600
Air outlet
H=20 or more
INSTALLATION OF INDOOR
Capacity (kBtu/h)
9
12 / 18
24
B(Min)
A(Min)
Service Space
B
7
(Unit: mm)
A
B
800
800
800
1000
800
1200
Ceiling
A