Download Print this page

NETGEAR APS150W Installation Manual page 2

For managed switches

Advertisement

5. Plug the AC power cord into a power source such as a wall socket or power
strip.
When you apply power, the AC OK LED on the PSU lights. The LED on the
switch for the power supply bay also lights. If these LEDs do not light, make
sure that the power cord is plugged in correctly and that the power source is
good.
Technical specifications
Specifications
PSU
AC input
• APS150W. 100–127VAC, 3A, 50–60 Hz or
200–240VAC, 1.5A, 50–60 Hz
• APS250W. 100–240VAC, 3.5–2A, 50–60 Hz
• APS299W. 100–240VAC, 5–2.5A, 50–60 Hz
• APS550W. 100–240VAC, 9–4A, 50–60 Hz
• APS600W. 90–132VAC, 8A, 47–63 Hz or
180–264VAC, 4A, 47–63 Hz
• APS750W. 100–240VAC, 10/5.36A max, 50–60 Hz
• APS1000W. 100–127VAC, 9.9A, 50–60 Hz or
200–240VAC, 7.8A, 50–60 Hz
• APS1200W. 90–132VAC, 15A, 43–67 Hz or
180–264VAC, 8A, 43–67 Hz
DC output
• APS150W. +12V, 12.5A
• APS250W. +12V, 20A or +12 VSB 1A
• APS299W. +54.5V, 5.51A
• APS550W. +54V, 10.95A or +12 VSB 2.08A
• APS600W. +54.5 VDC, 11A
• APS750W. +12V, 61.5A or +12VSB 3A
• APS1000W. 56V, 12.12A or +12 VSB 1.8A (@ 100–127VAC) 56V,
17.35A or +12 VSB 2.4A (@ 200–240VAC)
• APS1200W. +54.5 VDC, 22A @ 230 VAC, or 18.35A @ 115 VAC
© NETGEAR, Inc., NETGEAR and the NETGEAR Logo
are trademarks of NETGEAR, Inc. Any non‑NETGEAR
November 2019
trademarks are used for reference purposes only.
Specifications
PSU
Dimensions
• APS150W. 1.5 x 2.0 x 7.3 in. (39 x 50.5 x 185 mm)
(H x W x D)
• APS250W. 1.5 x 2.9 x 7.3 in. (39 x 74 x 185 mm)
• APS299W. 1.5 x 2.9 x 7.6 in. (39 x 74 x 194 mm)
• APS550W, APS1000W. 1.6 x 3.6 x 8.7 in. (40 x 87 x 208 mm)
• APS600W, APS1200W. 1.6 x 2.9 x 7.3 in. (40 x 73 x 185 mm)
• APS750W. 1.6 x 7.5 x 8.1 in. (40 x 192 x 206 mm)
• APS250W. 32 to 122ºF (0 to 50ºC)
Operating
temperature
• APS150W, APS299W, APS550W, APS600W, APS1000W,
APS1200W. 23 to 122ºF (–5 to 50ºC)
• APS750W. 32 to 131ºF (0 to 55ºC)
Operating
• APS150W. Up to 95% noncondensing
relative
• APS250W, APS299W, APS550W, APS600W, APS1000W,
humidity
APS1200W. 5% to 95% noncondensing
• APS750W. 10 to 90% noncondensing
Operating
• APS250W, APS550W, APS1000W. Up to 9,800 feet (3,000 m)
altitude level
above sea level
• APS150W , APS299W, APS600W, APS750W, APS1200W. Up to
16,000 feet (5,000 m) above sea level
Storage
• APS150W, APS250W, APS299W. –40 to 158ºF (–40 to 70ºC)
temperature
• APS550W, APS600W, APS1000, APS1200W. –40 to 185ºF (–40
to 85ºC )
Storage
Below 49,000 feet (15,000 m) above sea level
altitude level
MTBF
All models except APS750W. 4,534,733 hrs (~517 years) @ 77ºF
(25ºC)
APS750W only. 200,000 hrs (~23 years) @ 122ºF (50ºC)
Support
Thank you for purchasing this NETGEAR product. You can visit
https://www.netgear.com/support/
to register your product, get help, access the
latest downloads and user manuals, and join our community. We recommend
that you use only official NETGEAR support resources.
Si ce produit est vendu au Canada, vous pouvez accéder à ce document en
français canadien à https://www.netgear.com/support/download/.
(If this product is sold in Canada, you can access this document in Canadian
French at https://www.netgear.com/support/download/.)
For regulatory compliance information including the EU Declaration of
Conformity, visit https://www.netgear.com/about/regulatory/.
See the regulatory compliance document before connecting the power supply.
Do not use this device outdoors. If you connect cables or devices that are
outdoors to this device, see
https://kb.netgear.com/000057103
warranty information.
Compliance
Safety
IEC 60950-1, EN 60950-1, CB Certificate/Report, UL/CSA 60950-1
CE Low Voltage Directive 2006/95/EC (Europe)
CCC (China)
KC (Korea)
EMC
CC / ICES-003 Emission (USA/Canada)
EN61000-4-6 RF Conducted
CRISP 22 Emission (International)
EN61000-4-8 Power Frequency Magnetic Fields
EN55022 Emission (Europe)
EN61000-4-11 Voltage Dips and Interruptions
EN55024 Immunity (Europe)
EN61000-4-8 Power Frequency Magnetic Fields
EN61000-4-2 Electrostatic Discharge
EN61000-4-11 Voltage Dips and Interruptions
EN61000-4-3 Radiated RFI Immunity
EN61000-3-2 Harmonics (Europe)
EN61000-4-4 Electrical Fast Transients level 4
EN61000-3-3 Voltage Flicker (Europe)
EN61000-4-5 Electrical Surge Level
NETGEAR, Inc.
NETGEAR INTERNATIONAL LTD
350 East Plumeria Drive
Floor 1, Building 3
San Jose, CA 95134, USA
University Technology Centre
Curraheen Road, Cork,
T12EF21, Ireland
for safety and

Advertisement

loading

This manual is also suitable for:

Aps250wAps299wAps550wAps600wAps750wAps1000w ... Show all