Beka Hospitec KINET Operating Manual

Tilting bath tub
Table of Contents

Advertisement

Quick Links

Operating manual
Original operating manual
KINET
Tilting bath tub
Version 1.4/English
Subject to technical modifications
2019-04-10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KINET and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Beka Hospitec KINET

  • Page 1 Operating manual Original operating manual KINET Tilting bath tub Version 1.4/English Subject to technical modifications 2019-04-10...
  • Page 2: Table Of Contents

    Tub inlet with hand shower ................14 Thermostatic mixer ..................15 Tilt adjustment through handset ..............15 Tilt adjustment through buttons (options) ............15 Description of the symbols used ..............16 Operating element air spa system (option) ..........16 Operation ......................17 Description of the KINET tilting bath tub ............17...
  • Page 3 Disposal of the packaging material ..............23 11.2 Disposal of the product ................23 Troubleshooting/After-sales service ..............24 Appendix ......................26 13.1 Technical data .....................26 Dimensions of the KINET tilting bath tub ............27 13.2 13.3 Wiring diagram ....................28 13.4 Accessories ....................29 Spare parts/consumables ..............29 13.5...
  • Page 4: Imprint

    1.1 Acknowledgement Dear customer, we would like to express our sincere thanks for the trust you have placed in us by purchasing this BEKA Hospitec GmbH product. Our products are manufactured and tested according to stringent quality criteria. 1.2 Manufacturer’s address BEKA Hospitec GmbH Am Rübenmorgen 3...
  • Page 5: Introduction

    The maintenance, inspection, assembly and installation as well as well as further technical interventions on the product must only be executed by BEKA Hospitec either by specialised companies authorised to this effect by BEKA Hospitec. The operation of the product as well as technical interventions on the product must only be carried out by specially trained personnel.
  • Page 6: Operating Manual

    3.2 Type plate This image shows the type plate. The type plate is located on the frame of the KINET. The shown serial number (SN) 0582.09.17 is just an example. In case of queries, please mention the serial number printed on the type plate of your /Kinet device.
  • Page 7: Safety

    The KINET seat and shower bath tub offers a unique concept for a combination of bathing and safe showering. On the one hand, the patient is prevented from sliding...
  • Page 8: List Of Used Safety Instructions

    CE-label in accordance with the EC-Directive on Medical Devices. Solely intended for indoor use. Protection class II Protection against the penetration of liquids: Protection against IPX4 water splashing from all directions. Operating manual KINET V1.4 E Page 8 of 40...
  • Page 9: Warnings

    (current and equipotential bonding) for cable cracks. ▪ Repairs to components of the KINET tilting bath tub are to be carried out only by trained expert personnel. Please contact the after-sales service. The opening the device or other accessories will lead to the expiration of all guarantee, warranty and liability claims.
  • Page 10 (without wearing gloves) either with a thermometer. CAUTION In case of unusual noises, damages or malfunctions, the product no longer must be used. Operating manual KINET V1.4 E Page 10 of 40...
  • Page 11: Transport

    Remove the bubble wrap and the stretch film and/or the protective bag. NOTE Take care so as to not damage the product when using tools. Operating manual KINET V1.4 E Page 11 of 40...
  • Page 12: Installation

    The connection of the bath tub must be executed in accordance with the technical drawings issued by BEKA Hospitec either the guidelines for the set-up and layout of wet areas and the current VDE standards. All supply and drain hoses as well as the electrical cables must be installed so as to avoid the danger of tripping.
  • Page 13: First Start-Up

    Only when these conditions are met, the manufacturer considers himself responsible for the impact on the safety, the reliability and the function of the device. In the event of a new connection of an KINET tilting bath tub, the technical data must be observed. WARNING To prevent scalding, the hot/cold water mixer must be set up in accordance with the local water supply prior to the first use.
  • Page 14: Operating Elements And Their Function

    7.1 Tub inlet with hand shower Image 1: The image shows the valve for the hand shower and the tub inlet as well as the thermostat of the KINET tilting bath tub. Operating manual KINET V1.4 E Page 14 of 40...
  • Page 15: Thermostatic Mixer

    1: Button DOWN (tilt adjustment in reclined position) 2: Button UP (tilt adjustment in seated position) 7.4 Tilt adjustment through buttons (options) 1: Button DOWN (tilt adjustment in reclined position) 2: Button UP (tilt adjustment in seated position) Operating manual KINET V1.4 E Page 15 of 40...
  • Page 16: Description Of The Symbols Used

    The electrical motor is equipped with an overload protection, which automatically switches off in case of overload. The motor will only be operational again after a short waiting time (10-20 minutes). Opening the motor will result in expiration of the warranty. Operating manual KINET V1.4 E Page 16 of 40...
  • Page 17: Operation

    8 Operation 8.1 Description of the KINET tilting bath tub The KINET seat and shower bath tub offers a unique concept for a combination of bathing and safe showering. On the one hand, the patient is prevented from sliding down during showering by the unmatched ergonomic sitting position and on the other hand, the patient has the possibility to enjoy a full bath when the tub is tilted backwards.
  • Page 18: During Use

    If the desired filling Turn the thermostatic valve height is reached, to set the temperature. close the tub filling valve. Image 5: To use the hand shower, you must open the hand shower valve. Operating manual KINET V1.4 E Page 18 of 40...
  • Page 19: Stepping Out Of The Bath Tub

    Note! Please make sure that the bath tub is always disinfected and rinsed prior to use it for the next patient. To this effect, use for instance the hygienic wall shower panel D from BEKA Hospitec (article number: 930505050). Caution!
  • Page 20: Operation Of The Air Spa System (Option)

    30 minutes after the last button has been pressed, the system is switched off. In this way, it is ensured that the device does not remain unintended operational for a longer period of time. The automatic blow-dry can be switched off by manually pressing a button. Operating manual KINET V1.4 E Page 20 of 40...
  • Page 21: Cleaning/Disinfection

    9.1 Cleaning the tilting bath tub Clean the KINET tilting bath tub with a soft, lint-free cloth, moistened with soapy water or a standard plastic cleaner. Please do not use abrasives to clean the bath tub! To avoid damages, no aerosol cleaners, sprays, abrasive cleaners or solvents must be used to clean the keypad.
  • Page 22: Checks/Tests

    Checks/tests 10 Checks/tests In order to ensure a safe use of our KINET tilting bath tub and the protection of the users and the patients, BEKA Hospitec prescribes an annual safety check. The execution of the safety checks and maintenance must be documented and proven on request.
  • Page 23: Waste Disposal

    BEKA dealer, who will recycle the product in accordance with the locally applicable regulations and laws. For an environmentally-sound disposal, the company BEKA Hospitec GmbH will provide more information in its capacity of manufacturer. Please clean and disinfect the product prior to its disposal as well.
  • Page 24: Troubleshooting/After-Sales Service

    The air spa system fails during operation. c) Check if an air nozzle is blocked by a one-way valve. d) Check if possibly a hose of the air nozzles is buckled. Operating manual KINET V1.4 E Page 24 of 40...
  • Page 25 12 please contact the after-sales services of your dealer either the manufacturer. BEKA Hospitec GmbH Am Rübenmorgen 3 35582 Wetzlar Phone: +49(0)641-9 22 22-0 Fax: +49(0)641-9 22-22-20 info@beka-hospitec.de Operating manual KINET V1.4 E Page 25 of 40...
  • Page 26: Appendix

    800 – 1060 hPa - Atmospheric pressure: Storage and transport - Temperature range: -20° C to 70° C - Relative humidity: 10% to 80%, non-condensing 500 – 1100 hPA - Atmospheric pressure: Operating manual KINET V1.4 E Page 26 of 40...
  • Page 27: Dimensions Of The Kinet Tilting Bath Tub

    Appendix 13.2 Dimensions of the KINET tilting bath tub Operating manual KINET V1.4 E Page 27 of 40...
  • Page 28: Wiring Diagram

    Raumes, Fi-Schutzschalter – Nenn- Fehlerstrom max. 30mA, Elektroinstallation Electric connections must be done according nach den zur Zeit gültigen DIN/VDE to the rules and regulations for electric Normen systems in wet-rooms for each country. Operating manual KINET V1.4 E Page 28 of 40...
  • Page 29: Accessories

    Air spa bubble bath K0000150 Hand switch Spare parts/consumables Spare parts or consumables are available upon request from your BEKA Hospitec dealer or directly from the manufacturer. Please note: You cannot exchange and replace all spare parts by yourself. The assembly requires the knowhow of a qualified electrician/sanitary specialist.
  • Page 30: Declaration Of Conformity

    Appendix 13.5 Declaration of Conformity /KINET Operating manual KINET V1.4 E Page 30 of 40...
  • Page 31: Mounting Instructions

    Image 3: Loosen the Image 4: threaded pin from The image shows the hand shower the removed hand support and remove shower support. the support. Re-assemble in reversed order! Operating manual KINET V1.4 E Page 31 of 40...
  • Page 32: Checking And Removing The Drain Plug

    Check the proper function of the buttons. If the Insert the double functions are reversed, pull the double air hose air hose in the new out of the handset, turn the cable 180° and re- handset. insert. Operating manual KINET V1.4 E Page 32 of 40...
  • Page 33: Electromagnetic Compatibility

    Guidance and manufacturer’s declaration - electromagnetic immunity (Table 201) The KINET been designed for use in the hereafter listed ELECTROMAGNETIC ENVIRONMENTS. The customer or the user of the KINET must ensure that the appliance is used in such environment. Emission measurements...
  • Page 34 Guidance and manufacturer’s declaration - electromagnetic immunity (Table 202) The KINET been designed for use in the hereafter listed ELECTROMAGNETIC ENVIRONMENTS. The customer or the user of the KINET must ensure that the appliance is used in such environment. Immunity testing...
  • Page 35 KINET is to be used, exceeds the applicable HF compliance level, special care should be taken that a normal operation of the KINET can be guaranteed. In case anomalies are identified, additional measures could be required, such as a different alignment or a change of the location of the KINET.
  • Page 36 Recommended distance between portable and mobile communications equipment and the KINET (Table 206) The KINET is intended for use in an electromagnetic environment with controlled HF interferences. The customer or the user of the KINET can avoid electromagnetic interference by respecting and observing the minimum distance between portable and mobile HF telecommunication devices (transmitters) and the KINET depending on the rated output of the communication device as given below.
  • Page 37: Journal

    According to the Medical Device Directive, you are compelled to keep a journal for this device. You can use this journal as template. Journal KINET Device: Manufacturer: BEKA Hospitec GmbH, Am Rübenmorgen 3, 35582 Wetzlar Serial number: _____________________________________________ Date of purchase: _____________________________________________ Site: _____________________________________________...
  • Page 38 Appendix Type of Date Result Measure Signature: inspection Operating manual KINET V1.4 E Page 38 of 40...
  • Page 39 Appendix Your notes: …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… …………………………………………………………………………………………………… Operating manual KINET V1.4 E Page 39 of 40...
  • Page 40 BEKA Hospitec GmbH ●Am Rübenmorgen 3 ●35582 Wetzlar Germany● Phone/Fax:+49(0)6 41-9 22 20-0...

This manual is also suitable for:

910150700910150800

Table of Contents