Ambient Conditions

Max. ambient temperature
(surrounding air temperature)
Max. temperature gradient
Relative humidity
Air pressure
Mechanical strength
4.5

Used Standards

DOK-SUPPL*-IPC*40.2***-PR02-EN-P
Operation
+5 °C... +45 °C
Temporal temperature changes up to 3 °C
per minute
Climatic class 3K3 according to
EN 60721, condensation not permissible.
Up to 2000 m above sea level according
to DIN 60204
Max. vibration:
Frequency range: 10 ... 150 Hz
Excursion:
0.075 mm
for 10 ... 57 Hz
Acceleration:
1 g
for 57 ... 150 Hz
According to EN 60068-2-6
Fig. 4-4:
Ambient conditions
The system components of the IPC 40.2 correspond to the following
standards:
Standard
EN 60,204-1
EN 50,081-2
EN 50,082-2
EN 60,742
EN 60,950
EN 61,131
EN 61 131-2
EN 418
EN 60 529
EN 60 068-2-6
EN 60 068-2-27
Fig. 4-5:
Used standards
Note:
Concerning delivered IPC 40.2 all CE requirements are
fulfilled. After plugging-in extension cards, however, a new CE
test has to be executed.
Storage/transport
-20 °C to +60 °C
Not defined
Climatic class 3K3 according to
EN 60721, condensation not permissible.
Max. shock:
15 g according to
DIN IEC 68-2-27,
no disturbance of the function
Meaning
Electrical equipment of machines
Basic technical standard, emitted interference
(industrial environment)
Basic technical standard, noise immunity (industrial
environment)
Transformer for 24 V power supply unit, protective
separation
Overvoltage category II
Requirements concerning the 24 V outputs
Requirements concerning the 24 power supply
Machine safety, EMERGENCY STOP devices
Degrees of protection (incl. housings and installation
compartments)
Vibration test
Shock test