ADC TrueNet F/UTP Riser Cable Specification Sheet

Four pair f/utp riser cable

Advertisement

Quick Links

TrueNet
®
CopperTen
Four Pair F/UTP Riser Cable
®
ADC F/UTP CopperTen
®
for 10G shielded performance. Installed in high-performance networks world wide, the system's
design minimizes alien crosstalk and insertion loss and meets the performance requirements of
IEEE 802.3an, ISO 11801 Class EA and TIA/EIA-568-B.2-10 standards
Features:
Supports 10 Gigabit Ethernet over shielded copper to a full 100 meters
20 year TrueNet CopperTen warranty
w w w . a d c . c o m
cable can be used in data center, communications closet and work station
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
1 - 8 0 0 - 3 6 6 - 3 8 9 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the TrueNet F/UTP Riser Cable and is the answer not in the manual?

Questions and answers

Summary of Contents for ADC TrueNet F/UTP Riser Cable

  • Page 1 ® CopperTen Four Pair F/UTP Riser Cable ® ADC F/UTP CopperTen cable can be used in data center, communications closet and work station ® for 10G shielded performance. Installed in high-performance networks world wide, the system’s design minimizes alien crosstalk and insertion loss and meets the performance requirements of IEEE 802.3an, ISO 11801 Class EA and TIA/EIA-568-B.2-10 standards...
  • Page 2: Specifications

    TrueNet ® CopperTen Four Pair F/UTP Riser Cable ® Specifications CONSTRUCTION Conductor: Insulation: Separator: Shield: Drain Wire: Jacket: Nominal O.D.: COMPLIANCES UL Subject 444 (UL)-C(UL) Type CMR ICEA S-90-661 NEC 800 Type CMR TIA/EIA-568-B.2-1 Category 6 Horizontal Cable Requirements TIA/EIA-568-B.2-10 Augmented Category 6 Horizontal Cable Requirements ISO/IEC 11801 Category 6 Horizontal Cable Requirements ISO/IEC 11801 Category 6a Horizontal Cable Requirements COMMON APPLICATIONS...
  • Page 3 TrueNet ® CopperTen Four Pair F/UTP Riser Cable ® Fitted FREQ Impedance Ohms Spec 100 +/- 15 100 +/- 15 100 +/- 15 100 +/- 15 100 +/- 15 100 +/- 15 100 +/- 15 31.25 100 +/- 15 62.5 100 +/- 15 13.9 100 +/- 15...
  • Page 4 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.

This manual is also suitable for:

Truenet copperten