6.25.14

External Alarms (Horn and Lights)

Your service administrator may configure the control heads with external alarms (horn and lights) that
are activated when a Call Alert Page, Private Call, or Phone Call is received. The radio always powers
up with the horn and lights feature enabled.
6.25.14.1

Using Non-Permanent Horn and Lights

Procedure:
1 Press the Menu Select button directly below H/L momentarily.
The last selected alarm(s) are enabled, and the display shows the enabled alarm(s) alternating
with the selected mode, until it is turned off.
2 Press the Menu Select button directly below H/L momentarily to turn off the alarm(s).
The display shows HORN/LITES OFF.
6.25.14.2

Using Permanent Horn and Lights

When and where to use: If Permanent Horn and Lights is enabled, horn and lights will automatically
turn on when the radio powers up.
Procedure:
1 Press the Menu Select button directly below H/L once to turn off the alarm(s).
2 Press the Menu Select button directly below H/L momentarily to enable the last selected
alarm(s).
The display briefly shows the enabled alarms, and then reverts to the selected mode.
6.25.14.3

Changing the Selected Alarms

Procedure:
1 Press the Menu Select button directly below H/L until the display shows the required alarm.
2 Perform one of the following actions:
Press the Menu Select button directly below H+L to turn on both horn and lights.
Press the Menu Select button directly below Lgts to turn on the lights.
Press the Menu Select button directly below Horn to turn on the horn.
One of the following scenarios occurs:
If you choose H+L, the display shows HORN/LITES ON.
If you choose LGTS, the display shows LIGHTS ON.
If you choose HORN, the display shows HORN ON.
An OFF entry is shown at the softkey when one of the alarms is active. Selecting OFF
deactivates the current active alarm.