Telestream PRISM MPI2-25 Installation And Safety Instructions

Media analysis platform
Hide thumbs Also See for PRISM MPI2-25:

Advertisement

Quick Links

PRISM MPI2-25
Media Analysis Platform
Installation and Safety Instructions
This document supports software version 2.1 and above.
www.telestream.net
071-3730-00B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRISM MPI2-25 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Telestream PRISM MPI2-25

  • Page 1 PRISM MPI2-25 Media Analysis Platform Installation and Safety Instructions This document supports software version 2.1 and above. www.telestream.net 071-3730-00B...
  • Page 2 Copyright © 2020 Telestream, LLC and its Affiliates. All rights reserved. Telestream products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved.
  • Page 3 Telestream supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
  • Page 4 INCORPORATED WITHIN EQUIPMENT, CONTACT THE NEAREST TELESTREAM SALES OFFICE.) DEFINITIONS "Telestream" means Telestream, LLC, a Delaware limited liability company, and its Affiliates , or the local Telestream legal entity that is supplying the equipment. "Program" means the Telestream software product (executable program and/or data) enclosed with this Agreement or included within the equipment with which this Agreement is packed.
  • Page 5 TELESTREAM AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. LIMITATION OF LIABILITY, IN NO EVENT SHALL TELESTREAM OR OTHERS FROM WHOM TELESTREAM HAS OBTAINED A LICENSING RIGHT BE LIABLE FOR ANY INDIRECT,...
  • Page 7: Table Of Contents

    Table of Contents Important compliance and safety information ....................ii Preface ................................ix Product description ........................... ix Documentation ............................xi Conventions used in this manual ......................xi Installation ................................. 1 Initial product inspection ........................... 1 Accessories ............................... 2 Operating requirements ..........................3 Portable cabinet and dual rack cabinet installation ...................
  • Page 8: Important Compliance And Safety Information

    CAN/CSA-22.2 NO. 61010-1-12 + Gil + Gl2:: Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1: General Requirements. Sécurité CAN / CSA-22.2 NO. 61010-1-12 + Gil + Gl2 :: Exigences de sécurité pour l'électricité PRISM MPI2-25 Installation and Safety Instructions...
  • Page 9 For Compliance with the EMC standards listed here, high quality shielded interface cables should be used. Emissions which exceed the levels required by this standard may occur when this equipment is connected to a test object. Environmental Compliance This section provides information about the environmental impact of the product. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 10 This product is classified as an industrial monitoring and control instrument, and is not required to comply with the substance restrictions of the RoHS 3 Directives 2011 /65/EU and EU 2015/863 until July 22, 2021. This product does, however, comply with the RoHS 2 Directive 2011/65/EU. Korea Compliance Statement PRISM MPI2-25 Installation and Safety Instructions...
  • Page 11 When incorporating this equipment into a system, the safety of that system is the responsibility of the assembler of the system. To Avoid Fire or Personal Injury Use proper power cord: Use only the power cord specified for this product and certified for the country of use. Do not use PRISM MPI2-25 Installation and Safety Instructions...
  • Page 12 Be sure your work area meets applicable ergonomic standards. Consult with an ergonomics professional to avoid stress injuries. Use only the Telestream rackmount hardware specified for this product. Service Safety Summary The Service safety summary section contains additional information required to safely perform service on the product.
  • Page 13 Only qualified personnel who are aware of the hazards involved should remove the cover for repair, maintenance, or adjustment. Before use, always check the product with a known source to be sure it is operating correctly. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 14 CAUTION. To minimize the risk of damage to the instrument, we strongly recommend that the power cord be connected to the instrument before the power cord is connected to the AC power source. viii PRISM MPI2-25 Installation and Safety Instructions...
  • Page 15: Preface

    QoS levels in an increasingly complex broadcast environment involving compressed/uncompressed video transmission through SDI/IP signal paths. PRISM is an ideal solution for monitoring SDI/IP hybrid environments including master control rooms, production studios, OB vans, and signal contribution/distribution centers. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 16 Data Monitor PTP trend graphs to ensure proper IP system setup for robust sync system • Telestream patented Timing display showing the relative timing of the input signal and PTP • reference that makes facility timing easy 1 PPS output when the instrument is locked to a PTP reference •...
  • Page 17: Documentation

    PRISM MPI2-RACK- Instructions MD Rack Cabinet with touch display. Conventions used in this manual These icons may be used throughout this manual. Sequence Step Front panel Connect power Network SVGA power PRISM MPI2-25 Installation and Safety Instructions...
  • Page 19: Installation

    For the rest of the instrument, use a 75% isopropyl alcohol solution as a cleaner and rinse with deionized water. Before using any other type of cleaner, consult your Telestream Service Center or representative. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 20: Accessories

    Accessories Table 2: Standard and optional accessories Accessory Std. Opt. Telestream part number PRISM MPI2-25 Installation and Safety Instructions 071-3730-xx √ Power cord (See International power cords.) √ SFP and transceiver modules: SD/HD/3G Optical (1310 nm) SDI SFP transmitter module (to be MP-SFP Opt.
  • Page 21: Operating Requirements

    1/2 inch of clearance from the top of the instrument. sleeves) Portable Use only the Telestream portable cabinet, MPI2-PTBL, to ensure proper airflow with Cabinet this instrument. When using the portable cabinet, the same minimum clearances as the Bare Instrument apply. The portable cabinet also needs the ventilation requirement like one in the Bare Instrument.
  • Page 22 Dimensions Height 13.72 cm (5.4 in.) Width Chassis: 20.83 cm (8.2 in.) Bezel: 22.10 cm (8.7 in.) Depth 29.85 cm (11.75 in.) Weight Approximately 3.3 kg (7.3 lb.) Shipping Typically 10.64 kg (23.4 lb.) PRISM MPI2-25 Installation and Safety Instructions...
  • Page 23: Portable Cabinet And Dual Rack Cabinet Installation

    MPI-RACK-MW. Allows you to install one MPI2-25 unit or one MPI2-25 unit in a side- • by-side installation with a WFM52x0, WFM7200, or WFM8x00 instrument. The front of the cabinet has two USB ports and a headphone jack for one MPI2-25 unit. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 24: Connectors

    Connectors Figure 2 shows the external connections to the instrument. A description of each connector is provided in Table 6. Figure 2: PRISM rear panel Table 6: Descriptions of PRISM MPI2-25 rear panel connectors Item number Connector label, Figure 2...
  • Page 25 Ethernet port is a standard RJ-45 connector for 10/100/1000Base-T Ethernet cable. Audio input port is for future use. Audio output (1/8-inch—3.5mm—line out) port is for headphones to listen to the selected audio channel pair. Microphone input port is for future use. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 26: Sfp Module Installation

    An optical SFP module is shown above. Other types of SFP modules may have different latching mechanisms. SFP module transportation CAUTION. To prevent static damage to the SFP module, if you remove the SFP module from the instrument, always transport the SFP module in an anti-static bag or container. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 27: Power-On And Power-Off Procedures

    To minimize the risk of damage to the instrument, we strongly recommend that the power cord be connected to the instrument before the power cord is connected to the AC power source. Figure 4: Connecting the power cord to the instrument PRISM MPI2-25 Installation and Safety Instructions...
  • Page 28 To completely remove power from the instrument, disconnect the power cord from the instrument. The power cord has a locking mechanism to keep it attached to the instrument. Push the button on the cord housing to release the locking mechanism. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 30: Operation

    Application tabs. Some applications have selectable tabs (highlighted readouts) you can use to display additional information. Application tile 4. Application tile 2. The application panels can be shown in four-tile mode, full screen mode, or in vertical extended tile mode. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 31: Methods Of Operation

    The terms "press and hold", “ tap”, “swipe”, and “pinch” apply to the touchscreen on the instrument. If you are using a mouse and keyboard you must “click and hold”, “click”, “scroll” and use the scroll wheel on the mouse. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 32 Connect the Display Port output from the PRISM monitor to the input on the external device. • Connect the USB output of the external device to one of the USB ports on the PRISM monitor. • NOTE. A monitor with a 1920×1080 capable display works best with the instrument. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 33 IP address of the Control IP Port of the instrument. NOTE. If you have set a unique Hostname for the instrument, enter it in the browser address bar and select the noVNC Access link. This opens a login web page. (See Figure PRISM MPI2-25 Installation and Safety Instructions...
  • Page 34 Figure 9: noVNC login web page (See Figure In the Control bar, click the Connect icon to open the Connect dialog. 10.) In the Settings dialog box, enter the default password PRISM, and then click Connect. PRISM MPI2-25 Installation and Safety Instructions...
  • Page 35 Hostname, select Settings and then select Network, and select the Web Remote tab. Figure 10: noVNC login web page The Web browser connects to the instrument with the browser display appearing exactly like the instrument display, but with a slower update rate. PRISM MPI2-25 Installation and Safety Instructions...

Table of Contents